RA889A SWITCHING RELAY

3

68-0216—2

Cross Reference: The RA889A replaces many Honeywell
models. See Table 1 for additional cross reference
information.

Thermostat Compatibility: All Honeywell electromechanical
and most electromechanical 2- or 3-wire. Select thermostats
with 0.12A heating anticipator setting to match the electrical
rating of the switching relay.

Replacement Parts:
32002190-001 Replacement Relay.
Relay Fuse: 1A automotive fuse.

Table 1. RA889A Replacement Cross Reference.

a

RA889A has one set of COM/N.O. relay contacts. Use R8845U if two sets are required.

b

RA89A has lower output load rating. Check load requirements.

INSTALLATION

When Installing this Product . . .

1.

Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous condi-
tion.

2.

Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.

3.

Installer must be a trained, experienced service techni-
cian.

4.

After installation is complete, check out product opera-
tion as provided in these instructions.

5.

Follow local codes for installation and application.

WARNING

Electrical Shock Hazard.
Power supply can cause severe injury or death.
Transformer core not bonded.
Disconnect power supply before wiring.

MOUNTING

In replacement applications, mount the new relay in the same
location as the old relay. For new installations, locate the relay
vertically on a solid wall or partition as close as possible to the
device to be controlled. Select a location that is easily
accessible for installation and service.

NOTE:

To reduce the possible transformer hum and relay
noise that is sometimes amplified by mounting sur-
faces such as sheet metal, plasterboard, and similar
materials, place rubber or felt washers between the
case and the mounting surface.

1.

Position the relay and mark the mounting holes. See
Fig. 1.

2.

Start a screw in the upper right corner for the keyhole
type mounting hole. Screw it down within about 1/8 in.
(3 mm) of the surface.

3.

Hang the relay on the screw, position the case, and start
the bottom screw.

4.

Tighten both screws.

Manu-

facturer

Model

Connections

Comments

Input Line

Voltage

Power Relay

Low

Voltage

Relay

Thermostat

Honeywell RA889A

L1

L2

COM

N.O.

N.C.

X1

X2

W(T)

R(T)

C

Honeywell

RA89A

a

1

2

3

4

T

T

R182A

a

1

2

7

8

B

R

See Fig. 6
thermostat
connections

Jumper L1 to COM and between X1
and R(T) in RA889A.

R182B

1

2

8

6

7

B

R

Requires jumper between X1 and
R(T).

R182C

b

1

2

8

6

7

B

R

R482B

1

2

8

6

7

Jumper R(T) to
W(T).

Line voltage switched inputs go to L1
and L2. See Fig. 7B.

R482C

b

1

2

8

6

7

R482J

b

1

2

6

8

7

Line voltage inputs go to L1 and L2.
See Fig. 7B.

R882A

a

8

7

W

B

R882B

8

6

7

W

B

R882C

b

8

6

7

W

B

R882J

b

6

8

7

1

2