Honeywell F90B User Manual

Page 20

Advertising
background image

F90A,B SELF-CONTAINED COMMERCIAL ELECTRONIC AIR CLEANER

68-0103-6 Revised 11-07

20

1

1 TERMINAL BOARD FOR POWER SUPPLY CONNECTIONS.

POWER SUPPLY. PROVIDE DISCONNECT MEANS

AND OVERLOAD PROTECTION AS REQUIRED.

2 BROWN LEAD MUST BE CONNECTED TO TOP

TERMINAL ON TRANSFORMER.

3 INTERLOCK SAFETY SWITCH.

4 PROVIDES ON-OFF INDICATION.

5 LEFT CELL AND CONTACT BOARD ON
TWO-CELL AIR CLEANER ONLY.

M11577

5

BLACK

RED

TEST
BUTTON

CONTACT
BOARD

BROWN

VIOLET

BLUE

RED

FAN

MOTOR

3

WHITE

BROWN

230 Vac

A3

A4

B3

B4

C3

C4

D3

D4

A5

A6

B1

B2

C1

C2

D1

D2

OFF

LO

MED

HI

ORANGE

BLACK

ON-OFF/3-SPEED
FAN SWITCH

2

3

1

L

BLUE

N

WHITE

WHITE

4

RED IONIZER

BLACK COLLECTOR

LAMP

P3

P4

POWER
SUPPLY

2

PERFORMANCE
SWITCH

BLACK

BLACK

CHECK
(RED)

WASH
(YELLOW)

WHITE

RED

WHITE

RED

WHITE

RED

ON

(YELLOW)

J5

Fig. 24. F90A 230 Vac model schematic diagram (CE compliant model).

Advertising
This manual is related to the following products: