Fig. 13
KM-1601MRH/3
1. Icemaker
• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8"
nominal ID copper water tubing is recommended for the icemaker water supply line.
• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe is
recommended for the icemaker drain line. Condensation drain outlet is 3/8" OD hard
tube. The condensation drain line can be connected to the icemaker drain line or can
be run separately.
Icemaker Water Supply
Line Shut-Off Valve
Icemaker Water Supply
Line Drain Valve
Icemaker
Icemaker
Water Supply
Inlet
1/2" FPT
Bin Drain Outlet
3/4" FPT
Icemaker
Drain Outlet
3/4" FPT
Bin
Condensation
Drain Outlet
3/8" OD Hard Tube
Remote Condenser
Line Set Connections
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air
gap between the end of each pipe
and the drain.
2-inch (5-cm) air gap
Floor Drain
Vent Tube
Minimum 3/8" Nominal ID
Copper Water Tubing
Minimum 3/4" Nominal ID
Hard Pipe
Vent Tube