1. Icemaker

• Icemaker water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8"

nominal ID copper water tubing is recommended for the icemaker water supply line.

• An icemaker water supply line shut-off valve and drain valve should be installed.
• Icemaker drain outlet is 3/4" FPT. A minimum of 3/4" nominal ID hard pipe is

recommended for the icemaker drain line. Condensation drain outlet is 3/8" OD hard
tube. The condensation drain line can be connected to the icemaker drain line or can
be run separately.

Icemaker Water Supply

Line Shut-Off Valve

Icemaker Water Supply

Line Drain Valve

Icemaker

Icemaker

Water Supply

Inlet

1/2" FPT

Bin Drain Outlet

3/4" FPT

Icemaker

Drain Outlet

3/4" FPT

Bin

Condensation

Drain Outlet

3/8" OD Hard Tube

Remote Condenser

Line Set Connections

Separate piping to approved drain.

Leave a 2-inch (5-cm) vertical air

gap between the end of each pipe

and the drain.

2-inch (5-cm) air gap

Floor Drain

Vent Tube

Minimum 3/8" Nominal ID

Copper Water Tubing

Minimum 3/4" Nominal ID

Hard Pipe

Vent Tube