assembly

1.

Attach the Coil Air Hose to the Air Outlet as shown below.

2.

Regulator Pressure Gauge I (46)

Regulator Pressure Gauge II (50)

Coil Air Hose

Regulator Adjusting Knob (53)

Pressure Release Valve

Attach the Blow Gun (with desired tip), tire chuck, or other user supplied attachment
to the other end of the Coil Air Hose.

operation

turning Compressor on

1.

Plug the power cord into an electrical outlet with a grounding prong.

note: only use

a 115V electrical source (± 10% maximum variation.)

2.

Push the On/Off Switch to the ON position.

3.

Allow the Tank to fill to 80 PSI before using.

With the Air Compressor turned on, operation is automatic and under the control of
the internal pressure switch.

Internal Pressure Switch

Caution: do not make changes to the internal pressure level switch; any change to the
automatic on/off pressure levels will cause additional stress on the motor which may
result in shortened motor life. doing so will void the warranty.

using the Pressure relief Valve

The Pressure Relief Valve is used when decompression is needed quickly and efficiently.

1.

Press the On/Off Switch to the OFF position.

2.

Pull on the Pressure Release Valve ring to release pressure.

Caution: wear safety glasses. the released air is under high pressure and can cause
debris and dirt to fly as the air exits the tank.