7. installing gas supply – Hobart Welding Products OLYMPIC 30A OM-184 693C User Manual

Page 11

Advertising
background image

OM-184 693 Page 7

2-6.

Connecting To BETA-MIG

251 Welding Power Source

801 758-A

1

Spool Gun Control Module

See BETA-MIG

251 Owner’s

Manual for spool gun control
module installation instructions.

2

Gas Hose

Connect fitting to regulator/flow-
meter (see Section 2-7).

3

Trigger Control Cord

Insert plug into receptacle, and
tighten threaded collar.

4

Weld Cable

Connect to positive (+) weld output
terminal on welding power source
according to its Owner’s Manual.

Tools Needed:

1-1/8, 5/8 in

1

2

3

4

+

_

2-7.

Installing Gas Supply

ssb3.1* 5/94 – 158 697-A

Obtain gas cylinder and chain to
running gear, wall, or other station-
ary support so cylinder cannot fall
and break off valve.

1

Cap

2

Cylinder Valve

Remove cap, stand to side of
valve, and open valve slightly. Gas
flow blows dust and dirt from valve.
Close valve.

3

Cylinder

4

Regulator/Flowmeter

Install so face is vertical.

5

Gas Hose Connection

Fitting has 5/8-18 right-hand
threads.

6

Flow Adjust

Typical flow rate is 20 cfh (cubic
feet per hour). Check wire man-
ufacturer’s recommended flow
rate.

Make sure flow adjust is closed
when opening cylinder to avoid
damage to the flowmeter.

7

CO

2

Adapter

8

O-Ring

Install adapter with O-ring between
regulator/flowmeter and CO

2

cylinder.

Tools Needed:

1-1/8, 5/8 in

CO

2

Gas

7

8

3

1

2

4

5

6

1

2

3

Argon Gas

OR

Advertising