Temperature
settings do not
change

Make sure heating and cooling temperatures are set to acceptable ranges:

• Heat: 40° to 90°F (4.5° to 32°C).
• Cool: 50° to 99°F (10° to 37°C).

“Cool On” or
“Heat On” is
flashing

Compressor protection feature is engaged. Wait 5 minutes for the system

to restart safely, without damage to the compressor (see page 13).

“Heat On” is not
displayed

Set the System switch to Heat, and set the temperature level above the

current room temperature (see page 6).

“Cool On” is not
displayed

Set the System switch to Cool, and set the temperature level below the

current room temperature (see page 6).

To restore
Energy Star

®

default settings

Follow these steps to restore Energy Star default settings (see page 9):

1. Press

SET 3 times to display “Set Schedule.”

2. Press and hold

SET and RUN at the same time for 4 seconds.

3. Press

RUN.