Heath Zenith SH-5318 User Manual

Motion sensor light control with 2-level lighting, Operation, Models sh-5318

Advertising
background image

Models SH-5318

D

ual

B

rite

®

Motion Sensor

Light Control with

2-Level Lighting

© 2007 HeathCo LLC

598-1154-01

2 Shells*

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• D

ual

B

rite

®

Timer.

• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).

* Model SL-5318 only

This package includes:

Light Control

Sensor

Cover Plate

Lamp Holders

Plastic Hanger

Rubber Plug

Gasket

6 Screws

(3 sizes included)

Mounting Strap

Mounting Bolt

2 Wire

Connectors

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a
qualified electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

TEST

TEST 1 5 20

ON-TIME

Off 3 6 Dusk to

Dawn

D

ual

B

rite

®

Put ON-TIME switch
on the sensor bottom
to TEST and the D

ual

-

B

rite

®

switch OFF.

OPERATION

* resets to Auto Mode at dawn.

ON-TIME

TEST

1 5 20

... back on.

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5,
or 20 minute position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 20 Min

x

Manual

To Dawn*

x

Accent

3, 6 Hr, to Dawn

x

AUTO

MANUAL MODE

D

ual

B

rite

®

Timer

Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.

Move ON-TIME Switch to

1, 5, or 20 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

Advertising