background image

Motion Sensor Quartz

Security Light for

Canadian Tire

Model SL-5309

The Motion Sensor Quartz Security Light turns on 300
watts of quartz-halogen lighting when motion is detected
and then, after a selectable period of time, automati-
cally turns the lighting off. The built-in photocell keeps
the lighting off during daylight hours.

Cover

Plate

Sensor

3 Wire

Connectors

4 Screws

(2 sizes)

Light Control

Cover Plate

Gasket

© 2007 HeathCo LLC

598-1267-01

Halogen

Bulb

OPERATION

Move ON-TIME Switch

to 1, 5, or 10 minutes

Mode Switching Summary

Flip switch off for

one second then

back on*

* resets to Auto Mode at dawn.

TEST

AUTO

MANUAL MODE

ON-TIME

ON-TIME

Requirements

• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must

be wired through a switch – not a dimmer or other
electronic switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

• The backplate has knockouts so the sensor can be

mounted on most junction boxes.

• In some applications a universal adaptor plate may

be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the
calibration time (1

1

/

2

min.) the control will be in the

AUTO mode.

INSTALLATION

For easy installation, select an existing light with a wall
switch for replacement.

Attach the lamp arm to

the backplate arm and
secure with the long
bolt.

Note: When tightening the
arm screw, pull on the wires
to make sure the wires are not
pinched by the joint.

10 5 1

TEST

10 5 1 TEST

MANUAL MODE

AUTO

TEST

... back on.

1 Second OFF

then...

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Long Bolt

This package includes:

Put the ON-TIME switch on the bottom
of the sensor in the TEST position.

Put the ON-TIME switch in the 1, 5, or
10 minute position.

Mode:

On-Time

Works:

Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

x

Manual

Until Dawn*

x