Test and adjustment, Operation, Things to remember – Heath Zenith HEATH SL-7001 User Manual

Page 2: Adjustment of coverage area

Advertising
background image

2

595-5291-07

TEST AND ADJUSTMENT

NOTE: Sensor has a 30 second warm up period before
it will detect motion. When switching modes wait 30
seconds.

1. Slide the sensor switch to the TEST (center) posi-

tion.

2. Place the RANGE adjustment in the medium position

(halfway between MIN and MAX position).

Least Sensitive

Most Sensitive

Sensor

Motion

60 ft.
(18.3 m)

8 ft.
(2.4 m)

Maximum Range

Maximum

Coverage Angle

110°

RANGE

OFF

MIN

MAX

TEST

AUTO

Bottom of Sensor

Aim Sensor Down for

Short Coverage

Aim Sensor Higher for

Long Coverage

Ball Joint

Clamp Screw

Adjustment of Coverage Area

The sensor detects “motion” by the movement of heat
(body heat) across the coverage area. However, following
are examples of objects that also produce heat and can
cause the sensor to false trigger:
• Pools of Water

• Air Conditioners

• Dryer Vents

• Fenced-In Animals

• Heating Vents

• Automobile Traffic

If you suspect that a heat source of this type is falsely
triggering the sensor, try reducing the RANGE or aiming
the sensor away from the heat source in question.
Note: The detector is less sensitive to motion directly
towards it and more sensitive to across motion.

Motion

OPERATION

Place the sensor switch in AUTO for normal operation. If the
light is not needed, put the switch in the OFF position.

Mode:

On-Time

Works:

Day

Night

Test

5 Seconds

x

x

Auto

30 Seconds

x

THINGS TO REMEMBER

• Periodically clean the solar panel with a soft cloth and

warm water. Do not hose spray. Keep the collector clear
of snow and leaves. Make sure trees and other objects
do not block sunlight from the panel.

• If not to be used for several weeks, turn the unit OFF.

Store it with the panel connected and where the panel
can gather sunlight.

• Solar collection is only effective in direct sunlight. Every

hour the light is on requires a minimum of 16 hours of
sunlight charging. Solar panels collect less than 10%
of the sun’s energy. Light bulbs convert this energy to
light at 5% efficiency.

• Several days of use with overcast skies may discharge

the battery. Because of the battery protection circuit, the
light will not work until the battery is fully recharged.

• This light is supplied with a 15 Watt, bi-pin, halogen

bulb. For replacement, use Heath

®

/Zenith model SL-

7000-A1-A or equivalent. Note: Using a larger bulb will
decrease battery life.

3. Loosen the clamp screw in the sensor ball joint.

4. Walk through the coverage area noting when the lights

turn on. Gently move the sensor head up, down, or
sideways to change the coverage area. Note: Wait 5
to 10 seconds after light turns off to retest.

5. Increase RANGE only as needed. A larger RANGE

setting may cause false triggering and reduce battery
life.

6. Secure the sensor into position by tightening the clamp

screw. Do not overtighten the screw.

7. After dark, adjust the light to cover desired area.