Testing – Heath Zenith Dual Brite PF-4125-AZ User Manual

Page 6

Advertising
background image

6

598-1166-04

TESTING

Turn on the circuit breaker and light

switch.

If you need to change the sensitivity,

temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.

Set the amount of TIME you want the

light to stay on after motion is detected.
(1, 5, or 10 minutes).

Set the amount of time after dusk you

want the lights on accent level.

240°

Sensor Aiming

Adjustment Angle

Walk through the coverage area noting

where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area.

Note: Grasp the sensor
only as shown and turn
the entire sensor.

Any

other method may
damage the sensor.
Do not force it past
the stops.

Least Sensitive

Most Sensitive

30 ft.

(9.1m)

Maximum Range

Maximum

Coverage Angle

The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.

Sensor

Motion

Motion

6 ft.

(1.8 m)

Avoid aiming the control at:

Pools of water or objects that change
temperature rapidly, such as

heating vents

and air conditioners. These heat sources
could cause false triggering.

• Areas where

pets or traffic may trigger

the control.

Nearby large, light-colored objects reflect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.

Note: Sensor has a 1

1

/

2

minute warm up pe-

riod before it will detect motion. When
first turned on wait 1

1

/

2

minutes.

150°

TEST 1 5 10 MIN

ON-TIME

OFF 3 6 DUSK TO

HOUR DAWN

Note: Meets the ENERGY STAR

®

guidelines

when D

ual

B

rite

®

function is off.

Switch the on-time to TEST position and

D

ual

B

rite

®

switch to the OFF position.

Advertising
This manual is related to the following products: