Motion Detector Walk Test
IMPORTANT:
Before commencing walk test ensure the LED indicator behind the
detector lens is not flashing continuously. If it is wait until the detector has completed
its warm-up cycle and the flashing stops.
Configure the detector for walk testing according to the selected Day or Night operat-
ing mode as follows:

1) Set the TIME control fully counter-clockwise to its minimum setting.
2) If the detector is set to DAY operation (for use with a chime), adjust the DUSK

control fully counter-clockwise to its minimum setting. If the detector is set to
NIGHT operation (for use with lighting) adjust the DUSK control fully clockwise to
its maximum setting.

M27297

TIME

CONTROL

DUSK CONTROL

SETTING FOR

DAY OPERATION

DUSK CONTROL

SETTING FOR

NIGHT OPERATION

Fig. 5