Installation

General Information

NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.

NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor.

Grounding

WARNING

FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION HAZ-
ARD
on page 4.

D Pump: Use a ground wire and clamp as shown in

Fig. 1. Loosen the grounding lug locknut (W) and
washer (X). Insert one end of a 12 ga (1.5 mm

@)

minimum ground wire (Y) into the slot in lug (Z) and
tighten the locknut securely. Connect the other end
of the wire to a true earth ground. Order part num-
ber 237569 Grounding Clamp and Wire.

D Fluid and hydraulic hoses: Use only grounded

hoses with a maximum of 500 ft (150 m) combined
hose length to ensure grounding continuity.

D Hydraulic Power Supply: Follow the manufacturer’s

recommendations.

D Spray gun: Ground through connection to a prop-

erly grounded fluid hose and sprayer.

D Object being sprayed: Follow the local code.

D Fluid supply container: Follow the local code.

D Solvent pails used when flushing: Follow the local

code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the pail
on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.

D To maintain grounding continuity when flushing or

relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail, then
trigger the gun.