Henny Penny TROUBLESHOOTING HHC-990 User Manual

Page 3

Advertising
background image

Model HHC-990

E-6B

AIR TEMP SENSOR

• Faulty air temperature

FAILED SHORTED”

probe

“E-12A

WATER HEATER

• Faulty water

SENSOR FAILED

heater probe

OPEN”

“E-12B

WATER HEATER

• Faulty water

SENSOR FAILED

heater probe

CLOSED”

“E-17

HUMIDITY SENSOR

• Faulty humidity sensor

FAILED”

“E-18

NO WATER, FLOAT

• Float switch stuck or

SWITCH FAILED”

faulty; faulty relay

(stuck on);water pan
needs cleaned;
loose or faulty water
heater sensor; acorn nuts
on water heater cover
loose, or water heater
insulation missing or
damaged

A humidity error only shuts down the humidity system. If a humidity error occurs, and you want to
use the cabinet without humidity, turn the humidity off by following the directions for SP-4, Humidity
Setpoint, in Special Programming Section of this manual. Once the setpoint is off, the alarm stops,
but the error code shows in display. (Includes “E-12A”, “E-12B”, “E-17” and “E-18”).

5-2. ERROR CODES AND
WARNINGS (Continued)

Display

Cause

Panel Board Correction

• Turn switch to OFF position, then back to

ON; if the display shows “E-6”, the
temperature probe should be checked;
once the temperature probe is repaired, or
replaced, the controls should return to
normal; if “E-6”persists, have PC board
replaced

• Turn switch to OFF position, then back to

ON; if the display shows “E-12A”, the
water heater should be checked and
repaired or replaced (the water heater
probe is built into the water heater); the
controls should return to normal; if
“E-12A” persists, have PC board replaced

• Turn switch to OFF position, then back to

ON; if the display shows “E-12B”, the
water heater should be checked and
repaired or replaced (the water heater
probe is built into the water heater); the
controls should return to normal; if
“E-12B” persists, have PC board replaced

• Turn switch to OFF position, then back to

ON; if the display shows “E-17”, the
humidity sensor should be checked;
once the humidity sensor is repaired, or
replaced, the controls should return to
normal; if “E-17” persists, have PC board

replaced

• Turn switch to OFF position, then back to

ON; if the display shows “E-18”, check
and clean float switch; clean water pan;
have relay and water heater sensor
checked and replace if necessary; tighten
acorn nuts on water heater cover; make
sure insulation is under the water heater
cover; if “E-18” persists, have PC board
replaced

4-8

107