TESTING

Turn on the circuit breaker and light

switch.

Set the SENSITIVITY as needed. Too much

sensitivity may increase false triggering.

Set the amount of TIME you want the light

to stay on after motion is detected. (1, 5,
or 10 minutes).

240°

Sensor Aiming

Adjustment Angle

Walk through the coverage area noting

where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area.

Note: Grasp the sensor
only as shown and turn
the entire sensor.

Any

other method may
damage the sensor.
Do not force it past
the stops.

Least Sensitive

Most Sensitive

30 ft.

(9.1m)

Maximum Range

Maximum

Coverage Angle

The detector is less sensitive to motion di-
rectly towards it and more sensitive to across
motion.

Sensor

Motion

Motion

6 ft.

(1.8 m)

Avoid aiming the control at:

Pools of water or objects that change
temperature rapidly, such as

heating vents

and air conditioners. These heat sources
could cause false triggering.

• Areas where

pets or traffic may trigger

the control.

Nearby large, light-colored objects
reflecting daylight may trigger the shut-off
feature. Do not point other lights at the
sensor.

Note: Sensor has a 1

1

/

2

minute warm up pe-

riod before it will detect motion. When
first turned on wait 1

1

/

2

minutes.

TEST 1 5 10 MIN

ON-TIME

LO - M - HI

SENSITIVITY

150°

Set SENSITIVITY to mid position and

ON-TIME to TEST position.