IMPORTANT SAFETY INSTRUCTIONS

Read through all the instructions before starting to use the air-

conditioner. Keep this manual in a safe place for future reference.

1. Supervision is needed when the air-conditioner is used

anywhere near children. This appliance is not intended for use by

children or other persons without assistance or supervision if their

physical, sensory or mental capabilities prevent them from using

it safely.

2. Do not use the air-conditioner outdoors.

3. Stand the air-conditioner upright on a firm, even surface. Make

sure it is standing securely so that it cannot tilt or fall over. Water

can damage furniture and floor coverings.

4. Unwind the power cord completely. An incompletely unwound

power cord can lead to overheating and cause a fire.

5. If the power cord of the air-conditioner is damaged, it must be

repaired by a workshop that is approved by the manufacturer, as

special tools are needed.

6. Do not use an extension cord or a variable speed controller. This

can lead to overheating, fire or electric shock.

7. Only connect the air-conditioner with a single-phase earthed

power socket with the current stipulated on the type plate.

8. Switch the air-conditioner off and always pull the power plug

out of the power socket when the air-conditioner is not in use, or

when it is moved, handled or cleaned. Do not tug at the cord when

disconnecting the power plug.

9. The air-conditioner functions best at room temperatures of up

to 35°C.

10. Do not use the air-conditioner near easily inflammable gases

or materials, near an open fire, or in a location where oil or water

could splash. Do not spray insecticides or similar substances onto

the air-conditioner. Make sure that the air-conditioner is not

exposed to direct sunshine. Do not operate the air-conditioner in a

hothouse or a laundry, or near a bathtub, a shower or a swimming-

pool.

11. Do not use the air-conditioner outdoors. The air-conditioner is

intended only for domestic use indoors, in accordance with the user

manual, and is not intended for industrial use.

12. Before starting to operate the air-conditioner, make sure that

the air intakes (3, 8) and air outlet (1) are open. The air-conditioner

must not be positioned behind curtains or drapes, or behind other

objects or obstacles which could hinder the air circulation. Make

sure that no objects can get into the air intakes (3, 8) and air outlet

(1), as this can lead to overheating, fire or electric shock.

13. Do not direct the air outlet (1) directly towards people, plants,

pets, walls, furnishings or objects.

14. Do not pull the power plug out of the power socket when the

air-conditioner is in use. First press the power button to the

OFF position.

15. After switching the air-conditioner off, wait for 3-5 minutes

before switching it back on again, as the compressor could

otherwise be damaged.

16. Do not immerse the air-conditioner in water or any other

liquids and do not pour water or any other liquids over the unit or

into the air intake (8) or air outlet (1).

17. Clean the air-conditioner regularly by following the cleaning

instructions.

18. When you take the air filter out of the air-conditioner, make

sure that you do not touch any metal parts. These are sharp-edged

and could cause injury. Do not use the air-conditioner when the air

filter and air intakes (3, 8) are not installed.

19. If the power cord of the air-conditioner is damaged, it must be

repaired by a workshop that is approved by the manufacturer, as

special tools are needed.

20. Always transport the air-conditioner in an upright position.

If this is not possible, lay the unit on its side and stand it upright

as soon as you reach your destination. Wait at least 4 hours after

transporting the unit before starting to use it.

21. Do not operate the air-conditioner if it is damaged or looks as if

it might be damaged, or if it is not working properly. Pull the power

plug out of the power socket.

COMPONENTS

1. Air Outlet

2. Control Panel

3. Evaporator Air Intake

4. Air Outlet Hose

5. Casters

6. Power Supply with Plug

7. Drainage Pipe

8. Air Intake

9. Exhaust Nozzle

10. Exhaust Nozzle Connector ( pcs.)

11. Exhaust Hose

12. Flange Accessory Fixture

13. Window Connector Cap

WARNINGS

1. All wiring must comply with local and national electrical codes

and be installed by a qualified electrician If you have any questions

regarding the following instructions, contact a qualified electrician.
. Check available power supply and resolve any wiring problems

before installation and operation of this unit.
3. For your safety and protection, this unit is grounded through the

power cord plug when plugged into a matching wall outlet. If you

are not sure whether the wall outlets in your home are properly

grounded, please consult a electrician. Do not use plug adapters or

extension cords with this unit. If it is necessary to use an extension

cord with extension cord only ( available at most local hardware

stores).

INSTALLATION INSTRUCTIONS

Connect exhaust hose assembly to the back of the unit. Extend

hose to desired length and locate the exhaust nozzle through the

window for ventilation (Fig. 1).

Exhaust Duct Set Assembly and Installation

1. Insert ends of exhaust hose (11) into exhaust nozzle connector

(10) by twisting counter-clockwise until it stops.
. Attach one exhaust nozzle connector (10) onto the rear outlet of

the unit. This is achieved by sliding the exhaust nozzle connector of

hose downward over the exhaust outlet of unit (4) ensuring that

ENGLISH