598-1351-01

SYMPTOM

Lights stay on

continuously.

Lights flash on

and off.

POSSIBLE CAUSE

1. A flood lamp is positioned too close to

the sensor or pointed at nearby objects

that cause heat to trigger the sensor.

(Reposition the lamp away from the

sensor or nearby objects).

2. Light control is pointed toward a heat

source like an air vent, dryer vent, or

brightly-painted heat-reflective sur-

face. (Reposition sensor).

3. Light control is in Test. (Set control

switch to an ON-TIME position).

1. Heat or light from the lamps may be

turning the light control on and off.

(Reposition the lamps away from the

sensor).

2. Heat being reflected from other objects

may be affecting the sensor. (Reposi-

tion sensor).

3. Light control is in the Test mode and

warming up. (Flashing is normal under

these conditions).

4. Light may be leaking through the flood

lamp reflectors. (Make sure the metal

lamp protectors are installed).

TROUBLESHOOTING GUIDE

TWO YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary
from state to state or province to province.
For a period of two years from the date of purchase, any malfunction caused by factory defective parts or
workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs,
batteries, and other expendable items are not covered by this warranty. Unauthorized service or modifica-
tion of the product or of any furnished component will void this warranty in its entirety. This warranty does
not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or
return shipping charges.
Please keep your dated sales receipt, it is required for all warranty requests.

SYMPTOM

Lights will not come

on.

Lights come on in

daylight.

Lights come on

for no apparent

reason.

POSSIBLE CAUSE

1. Light switch is turned off.

2. Flood light is loose or burned

out.

3. Fuse is blown or circuit breaker

is turned off.

4. Daylight turn-off is in effect (re-

check after dark).

5. Incorrect circuit wiring, if this is a

new installation.

6. Re-aim the sensor to cover de-

sired area.

1. Light control may be installed in

a relatively dark location.

2. Light control is in Test. (Set

control switch to an ON-TIME

position).

1. Light control may be sensing

small animals or automobile traf-

fic (re-aim sensor).

2. Range is set too high. (Reduce

Range).

TECHNICAL SERvICE

Please call 1-866-534-9718 (English speaking only) for assistance before returning product to store.

If you experience a problem, follow this guide. If the problem persists, call* for assistance at

1-866-534-9718

(English speaking only)

, 8:00 AM to 6:00 PM CST (M-F).

* If contacting Technical Service, please have the following information available: Model Number, Date of Pur-
chase, and Place of Purchase.

No Service Parts Available for this Product

Please keep your dated sales receipt, it is required for all warranty requests.