Tradeline models, Standard models – Honeywell R841C-E User Manual

Page 2

Advertising
background image

IMPORTANT

THE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES.
THEREFORE, THIS UNIT MAY NOT MATCH THE LISTED SPECIFICATIONS EXACTLY .ALSO, THIS PRODUCT IS TESTED
AND CALIBRATED UNDER CLOSELY CONTROLLED CONDITIONS, AND SOME MINOR DIFFERENCES IN PERFOR-
MANCE CAN BE EXPECTED IF THOSE CONDITIONS ARE CHANGED.

TRADELINE MODELS

TRADELINE models are selected and packaged to provide ease of stocking, ease of handling, and maximum

replacement value. TRADELINE model specifications are the same as those of standard models except as noted
below.

TRADELINE MODELS A VA

R841D–24

Vat,

60

Hz.

D, and E Electric Heating Relays.

208, 240, 277 Vat; 50/60 Hz.

VOLTAGE AND FREQUENCY:

ADDITIONAL FEATURES: TRADELINE pack with

Vat, 60 Hz.

cross reference label and special instruction sheet.

STANDARD MODELS

MODELS: R841 Electric Heating Relay.

R841 C Electric Heating Relay –with integral trans-

former, with conduit bushing; includes one spst
snap switch.

R841 D Electric Heating Relay –without transformer,

with conduit bushing; includes one spst snap switch.

R841 E Electric Heating Relay–with integral trans-

former, with conduit bushing; includes two spst
switches.

VOLTAGE AND FREQUENCY:

R841C (with transformer)– 120, 208, or 277 Vac at

60 Hz; 240 Vac at 50/60 Hz.

R841 D (without transformer)–24 Vat, 60 Hz.

(with

20, 208, 240, or 277

Vac at 50/60 Hz,

SWITCH: MICRO SWITCH snap switch,

oper-

ated. Makes contact about 75 seconds (cold) after
thermostat calls for heat. (Top stitch on R841 E
with optional specification makes at about 55 seconds,
bottom switch at about 75 seconds. ) Breaks contact
about 65 seconds (hot) after thermostat shuts off,

ELECTRICAL RATINGS (A per switch, 60 Hz current):

Noninductive Rating: 22 A at 120, 208 and 24(I Vac;

19 A at 277 Vat.

THERMOSTAT HEAT ANTICIPATOR CURRENT:

A.

R841 E –0.4 A (one thermostat controlling both loads);

0.2 A (one thermostat controlling each load).

AMBIENT TEMPERATURE RANGE: Minus 20 F to

plus 150 F [minus 29 C to 66 C].

UNDERWRITERS LABORATORIES INC. LISTED

and E): File No. E4436, Guide XAPX.

CANADIAN STANDARDS ASSOCIATION CERTI-

FIED:

No. LR1620 and LR1322.

R841E–File No.

(continued on page

WHEN PURCHASING REPLACEMENT AND MODERNIZATION PRODUCTS FROM YOUR TRADELINE
WHOLESALER OR YOUR DISTRIBUTOR, REFER TO THE TRADELINE CATALOG OR PRICE SHEETS FOR

COMPLETE ORDERING NUMBER, OR

1. Order number; specify TRADE LINE,

2. Voltage and frequency.

if desired.

3. Optional specification, if desired.

IF YOU HAVE ADDITIONAL QUESTIONS, NEED FURTHER INFORMATION, OR WOULD LIKE TO COMMENT ON OUR
PRODUCTS OR SERVICES, PLEASE WRITE OR PHONE:

I

.

YOUR LOCAL

HONEywELL Residential DIVISION

SALES

OF

DIREcToRY).

2. RESIDENTIAL DIVISION CUSTOMER SERVICE

HONEYWELL INC., 1885 DOUGLAS DRIVE NORTH
Ml

MINNESOTA 55422 (612) 542-7500

(IN CANADA–HONEYWELL

CONTROLS LIMITED,

740 ELLESMERE ROAD, SCARBOROUGH, ONTARIO MIP

INTERNATIONAL SALES AND SERVICE OFFICES IN ALL PRINCIPAL CITIES OF THE WORLD.

2

Advertising