Spark arrester service, Servicing your honda stick edger 23 – HONDA HHE31C User Manual

Page 25

Advertising
background image

SERVICING YOUR HONDA STICK EDGER

23

Spark Arrester Service

The spark arrester must be serviced every 100
hours to keep it functioning as designed.

If the engine has been running, the muffler will
be very hot. Allow the muffler to cool before
servicing the spark arrester.

1. Remove the four 5 x 18 mm bolts from the

recoil starter, and remove the recoil starter.

2. Disconnect the spark plug cap from the

spark plug. Pull the spark plug wire and the
ignition switch wire out of the retainers in the
top cover.

3. Remove the two 5 x 22 mm bolts from the

top cover, and remove the top cover.

4. Remove the three 5 mm screws from the

muffler cover, and remove the muffler cover.

5. Remove the 4 mm screw from the spark

arrester, and remove the spark arrester.

RECOIL STARTER

5 x 18 mm BOLTS

RETAINERS

SPARK
PLUG
CAP

SPARK
PLUG
WIRE

IGNITION
SWITCH
WIRE

5 x 22 mm
BOLTS

TOP
COVER

MUFFLER

SPARK
ARRESTER

5 x 16 mm SCREW

MUFFLER
COVER

5 x 10 mm SCREW

4 mm SCREW

Advertising