Hotpoint HXB9LSX User Manual

Page 11

Advertising
background image

11

EN

CONTROLS

To select the functions of the hood just touch the commands.


T1. ON/OFF Lights
T2. Speed decrease
Press

key

"T2" to decrease the speed from 4 (intensive) to 1.

Press

key

"T2" during operation at speed 1, the hood moves to OFF state.

T3. Speed increase
Press

button

T3 and the hood moves to OFF state at speed 1.

Press the button (hood in ON state) to increase the motor speed from 1 to
the intensive speed (timed).

Speed 1 LED L1

Speed 2 LED L1+L2

Speed 3 LED L1+L2+L3

Intensive speed (timed) LED L1+L2+L3+L4 flashing

Note: Speed 4 (intensive timed) keeps on for 5 minutes, after that the hood

sets speed 2 automatically

T4. Speed timing / Filter saturation signal control and configuration

Speed timing:

The speed timing is activated by pressing key T4, when the timing has
elapsed the hood switches off.

The timing is divided as follows:

Speed 1 - 20 minutes (LED L1 flashing)

Speed 2 - 15 minutes (LED L1+L2 flashing)

Speed 3 - 10 minutes (LED L1+L2+L3 flashing)

Intensive Speed - 5 minutes (LED L1+L2+L3+L4 flashing)

During the timed operation, press key T2 and the hood quits the timed
mode and decreases the speed.

Press

key

T3 and the hood quits the timed mode and increases the speed.

Press

key

T4 and the hood quits the timed mode keeping the speed set.

Filter saturation signal control and configuration

Grease filter signal

After 80 working hours LED L1 flashes.

When such signal appears, carry out the maintenance of the grease
filter.

To reset the signal: with hood on, keep key T4 pressed for 5”.

The hood gives out a "BEEP" and then it switches off; LED L1 stops
flashing.

Charcoal filter signal

After 320 working hours LED L2 flashes.

When such signal appears, carry out the maintenance of the charcoal
filter.

To reset the signal: with hood on, keep key T4 pressed for 5”.

The hood gives out a "BEEP" and then it switches off; LED L2 stops
flashing.


In the case of contemporaneous signaling of both filters, LEDs L1 and L2
flash.

The signal is reset by carrying out the procedure described above 2 times.

The first time it resets the charcoal filter signal, the second time it resets the
grease filter signal.


Note: In the standard mode the charcoal filter signal is not active.

When the hood is used in filter version, activate the charcoal filter
signal.


Activating charcoal filter signal:

Set the hood to OFF and keep key "T4" pressed for 5”.

As soon as the key is pressed, the relevant LEDs of the signals of the filters
currently active will light up. Keep pressing, the hood will give out a "BEEP"
and LED L2 will flash for 2".

LEDs

L1 and L2 remain on for about 2" before the hood gets back to OFF

state.

Deactivating charcoal filter signal:

Set the hood to OFF and keep key "T4" pressed for 5”.

As soon as the key is pressed, the relevant LEDs of the signals of the filters
currently active will light up. Keep pressing, the hood will give out a "BEEP"
and LED L2 will switch off.

LED

L1 remains on for about 2" before the hood gets back to OFF state.


T5. Sensor control key (ON-Automatic mode / OFF-Manual mode):

Automatic operating mode (COOKING)

The system is set by default to the "manual operating mode", to activate
the "automatic operating mode" press key "T5".

With hood off: LEDs L1+L4 switch on

With hood on: the LED of the speed selected switches on while the other
LEDs start flashing.

During cooking, the system promptly reacts to Vapour/Gas increases: it
switches the hood on at the most suitable speed and keeps working at the
same speed for at least 1 minute, before getting back to the lowest
speed/switching off.

When cooking is over and the environmental parameters are back on the
levels prior to cooking the system switches off.

Note: If the parameters are close to the rest condition the system

forces the hood switching-off after 30 minutes.

It is possible to deactivate the " automatic operating mode" as follows:

- Press key "T5" and the motor gets back to the "manual operating
mode
".

Note: it is also possible to get back to the manual operating mode by
pressing keys "T2", "T3" or "T6", the system decreases ("T2"),
increases ("T3") the motor speed or switches ("T6") the hood off.


T6. ON/OFF Suction motor:
With hood on at any speed, press key "T6" and

the hood switches off.

With hood off, press key "T6" and the hood switches on at Speed 1.


Selection of the hob
This operation is necessary to optimize the automatic functioning of the hood,
according to the type of hob selected.
Note: The hob set by default is the Gas hob.
To select a different hob (or to check the hob set) follow the instructions below:
Set the hood to OFF
Press keys "T2" and "T3" contemporaneously for about 5 seconds until the hob
being used is displayed (the hood gives out a "BEEP" signal).
Gas hob: LED "L1" on
Induction hob: LED "L2" on
Electric hob: LED "L3" on
The cyclical selection of the hob is possible by pressing keys "T2" or "T3".
Once the hob has been selected, wait for 10” to accept the function.
The acceptance of the hob selected is displayed by the sequence of 3 flashes of
the relevant LED of the hob selected.
After selecting the hob it is necessary to carry out the "Sensor calibration"
again.

Sensor calibration (Automatic or Manual)
In order that the sensor responds correctly to the thermal stresses produced by
the hob below it is necessary to calibrate the sensor.
Note:
before calibrating the sensor carry out the "Selection of the hob",

see previous paragraph.

Note: Carry out the calibration when installing the hood for the first time,

after a long period of non-use or a blackout.

The calibration must be carried out with motor off.


Automatic calibration of the sensor
The automatic calibration of the sensor starts as soon as the hood is fed (visible
by pressing key T5), LEDs L1+L4 flash for a period of time that can vary
according to the hob selected, however no longer than fifteen minutes

Advertising