Symbology – Harbor Freight Tools Chicago Electric LED Work Light 66308 User Manual

Page 5

Advertising
background image

SKU 66308

For technical questions, please call 1-800-444-3353.

Page 5

can carry a higher current than a 16

gauge cord.

(See table A.)

When using more than one exten-

4.

sion cord to make up the total length,

make sure each cord contains at least

the minimum wire size required.

(See

table A.)
If you are using one extension cord

5.

for more than one tool, add the name-

plate

amperes and use the sum to

determine the required minimum cord

size.

(See table A.)

If you are using an extension cord

6.

outdoors, make sure it is marked with

the suffix “W-A” (“W” in Canada) to

indicate it is acceptable for outdoor

use.
Make sure the extension cord is

7.

properly wired and in good electrical

condition. Always replace a damaged

extension cord or have it repaired by

a qualified electrician before using it.
Protect the extension cords from

8.

sharp objects, excessive heat, and

damp or wet areas.

recommended minimum wire

gAuge For eXtenSion cordS*

(120/240 VOLT)

nAmeplAte

AmpereS

(at full load)

eXtenSion cord

length

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

tABle A

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.

Symbology

Double Insulated

Canadian Standards

Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per

Minute (RPM)

Advertising