Five wires connected to the old thermostat, Use the table below to wire the new thermostat – Honeywell MAGICSTAT CT3300 User Manual

Page 10

Advertising
background image

10

INSTALLATION

69-0654-5

M20127

JUMPER (FACTORY-
INSTALLED). REMOVE
IF 5-WIRE SYSTEM

R

Rc

W

Y

G

Five wires connected to the old thermostat

Your new thermostat has a factory-installed metal jumper between the R and Rc terminals (Fig. 15). Remove the jumper
before wiring the R and Rc terminals.

Fig. 15

Old thermostat terminals that do not match new thermostat terminals

Use the table below to wire the new thermostat.

*Remove factory-installed jumper between R and Rc terminals in 5-wire systems.

Old thermostat
terminal

Connect to new
thermostat terminal Description

R, RH, 4, V

R*

Power

Rc, R

Rc*

Power for cooling

W, W

1

, H

W

Heat

Y, Y

1

, M

Y

Cooling

G, F

G

Fan

O

Do not continue
installation

Changeover in cool (O terminal) or changeover in heat (B terminal).
You have a single stage heat pump or zoning system. See page 2 for an
alternate thermostat model.

B

C, X, B

Do not connect

Transformer common.

W

2

, H

2

Do not continue
installation.

Second stage heat (W

2

, H

2

) or second stage cooling (Y

2

).

You have a multistage heating/cooling system. See page 2 for an alternate
thermostat model.

Y

2

Advertising