e) Bin Control Selector (S1 dip switch 7)

This unit is factory set for infrared sensor bin control operation. No adjustment is
required. When used on a standard ice storage bin, the mechanical bin control may be
used instead of the infrared sensor by moving S1 dip switch 7 to the off position. In the
factory default position (S1 dip switch 7 in the on position), the gear motor delay after the
upper float switch closes is 30 seconds. When the mechanical bin control is used (S1 dip
switch 7 in the off position), the gear motor delay after the upper float switch closes is
5 seconds.

WARNING! Do not place S1 dip switch 7 in the off position on dispenser

unit applications.

S1 Dip Switch

Setting

Bin Control Application

Gear Motor Delay

No. 7

OFF

Mechanical Bin Control (Standard Ice Storage Bins Only)

5 seconds

ON

Infrared Sensor with
Mechanical Bin Control Backup

30 seconds

f) Mechanical Bin Control Shutdown Delay (S1 dip switch 8)

Factory set for normal operation. No adjustment is required. The shutdown delay is the
time between the mechanical bin control proximity switch opening and the control board
shutting off the icemaker.

S1 Dip Switch

Setting

Bin Control #1

Shutdown Delay

No. 8

OFF

0.25 Seconds

ON

6.7 Seconds

g) Factory Use (S1 Dip Switch 9 & 10)

Factory set for optimum performance. Do not adjust.