Performance Data & Specifications

Model ltA

Air defrost

Model

Capacity

fan data

Shaded Pole Motor

10ºf td

5ºf SSt

6ºC TD

-4ºC SST no. CfM m

3

H hP

115/1/60

08-30/1/60

BtUh

Watts

Amps Watts Amps Watts

LTA053

5,300

1,550

2

850 1,450 1/20

3.6

220

.0

200

LTA079

7,900

2,310

3

1,350 2,300 1/20

5.4

330

3.0

300

LTA102

10,00

2,990

4

1,800 3,100 1/20

7.

440

4.0

400

LTA134

13,400

3,930

5

,50 3,850 1/20

9.0

550

5.0

500

LTA172

17,00

5,040

6

,550 4,350 1/20 10.8

660

6.0

600

Model ltl

Electric defrost

Model

Capacity

fan data

Shaded Pole Motor defrost heaters

10ºf td

-10ºf SSt

6ºC TD

-23ºC SST no. CfM m

3

H hP 08-30/1/60 08-30/1/60

BtUh

Watts

Amps Watts Amps Watts

LTL046BA

4,600

1,350

2

850 1,450 1/20

.0

200

4.8

1,100

LTL068BA

6,800

1,990

3

1,300 2,200 1/20

3.0

300

7.

1,650

LTL093BA

9,300

2,720

4

1,700 2,900 1/20

4.0

400

9.6

2,200

LTL115BA

11,500

3,370

5

,100 3,600 1/20

5.0

500

1.0

2,750

LTL133BA

13,300

3,900

6

,550 4,350 1/20

6.0

600

14.4

3,300

Capacity Correction factor

Electric defrost Units

Saturated Suction

Temperature ºF

+20 -10 -20

Saturated Suction

Temperature ºC

-7

-23 -29

Multiply Capacity

By

1.11 1.00 0.96

* Suction connection is swedged to directly accept piping

Model ltA

Air defrost

Model

no.

of

fans

Connections (in.)

Approx.

net Wt.

(lbs.)

Coil inlet

od

Suction

id

External

Equalizer od

drain

MPt

LTA053

2

1/2

5/8

1/4

3/4

48

LTA079

3

1/2

5/8

1/4

3/4

69

LTA102

4

1/2

7/8

1/4

3/4

85

LTA134

5

1/2

7/8

1/4

3/4

108

LTA172

6

1/2

1-1/8

1/4

3/4

124

Model ltl

Electric defrost

Model

no.

of

fans

Connections (in.)

Approx.

net Wt.

(lbs.)

Coil inlet

od

Suction

id

External

Equalizer od

drain

MPt

LTL046

2

1/2

5/8

1/4

3/4

48

LTL068

3

1/2

5/8

1/4

3/4

69

LTL093

4

1/2

7/8

1/4

3/4

85

LTL115

5

1/2

7/8

1/4

3/4

108

LTL133

6

1/2

1-1/8

1/4

3/4

124

dimensional data for All Models

Air

defrost

Electric

defrost

no. of

fans

dimensions

A

B

C

d

in.

mm

in.

mm

in.

mm

in.

mm

LTA053

LTL046

2

49-3/8

1,254

40-7/8

1,038

-

-

-

-

LTA079

LTL068

3

69-1/8

1,756

60-5/8

1,540

-

-

-

-

LTA102

LTL093

4

88-7/8

2,257

80-3/8

2,042

40-7/8

1,038

-

-

LTA134

LTL115

5

108-5/8

2,759

100-1/8

2,543

40-7/8

1,038

-

-

LTA172

LTL133

6

18-3/8

3,261

119-7/8

3,045

40-7/8

1,038

39-1/

1,003

Physical Data