Inspection:

You risk electric shock if you operate this generator with a faulty GFCI
(ground fault circuit interrupter).

Test GFCI before use.

If the GFCI fails testing, do not use your generator. Contact your
Honda dealer.

CIRCUIT BREAKER

GFCI RESET BUTTON

GFCI TEST BUTTON

OFF

Always check GFCI operation before using the generator.

Unplug all tools and appliances from the generator.

Start the engine.

Turn the circuit breaker to the ON position.

Turn the Auto Throttle switch to the OFF position.

Press the GFCI TEST button. The RESET button should extend, and
the circuit breaker should switch to the OFF position.

If the GFCI and circuit breaker do not function as described, take the
generator to an authorized Honda generator dealer for repair.