23

AC Receptacle Selection

Power Producing Circuits

EB3800X:

120V/240V

POWER
CIRCUIT 1

POWER
CIRCUIT 2

POWER CIRCUIT 1

POWER CIRCUIT 2

120V ONLY

120V 30A
120V 20A (in total)
120V 20A (in total)

&

120/240V 20A

4B

4A

4A

4B

The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle

4, the 240-volt receptacle, has two

powered terminals, 4A and 4B.

This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.