English, Disconnect battery charger from the receptacle, Remove the battery from the battery charger – HTC DS18DMR User Manual

Page 18

Advertising
background image

English

18

Lamp indications

Status lamp

Charging time

Lights

Lights continuously

30 minutes until charging complete.

Charge

30 minutes

red

time

Charging time

Lights

Lights continuously

20 minutes until charging complete.

lamp

20 minutes

orange

(red/

Charging time

Lights

Lights continuously

5 minutes until charging complete.

orange/

5 minutes

green

green)

Overheat standby

Blinks

Lights for 0.3 seconds, off 0.3 seconds

Battery overheated. Unable to charge.

red

(Charging will commence when battery cools.)

Charge

Before charging

Blinks

Lights for 0.5 seconds, off 0.5 seconds

Power cord is connected to

status

red

receptacle.

lamp

Charging complete

Lights

Lights continuously

(red/

green

orange/

Charging

Blinks

Lights for 0.1 seconds, off 0.1 seconds

Battery or charger malfunction.

green)

impossible

orange

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Table 4

Lamp indications

(2) Regarding the temperature of the rechargeable battery

The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.

Table 5

Recharging of batteries that have become hot

4. Disconnect battery charger from the receptacle.

CAUTION:

Do not pull the plug out of the receptacle by pulling on the cord.
Make sure to grasp the plug when removing from receptacle to avoid damaging cord.

5. Remove the battery from the battery charger.

Supporting the battery charger with hand, pull out the battery from the battery charger.

CAUTION:

Repair is required if the receptacle is not secured properly or the power cord does not
stay in the receptacle. Consult your electrician. Using the charger in this condition
may lead to fire.

If the charge status lamp is blinking orange rapidly (in 0.2 second intervals) and the
buzzer sounds intermittently for 5 seconds, check that the hole for connecting the
battery is not obstructed. Remove any obstructions. If no obstructions are found, the
battery or charger may be malfunctioned. Return both to your place of purchase.

If the charge time lamp does not light when the power cord is connected to the
receptacle, disconnect the power cord, and check that the battery is attached correctly.

The battery retains heat when used or left for prolonged periods in direct sunlight. In
this state, the charge time lamp flashes red, and the battery cannot be charged
immediately. Leave the battery inserted in the charger, and charging will commence
when the battery cools down.

Rechargeable batteries

Temperatures at which the battery can be recharged

EB1830HL

32°F—122°F (0°C—50°C)

Advertising