Installation, Vertical termination with co-linear flex system – Hampton Direct H25-NG1 User Manual

Page 18

Advertising
background image

18

Hampton

®

H25-1 Direct Vent Freestanding Gas Stove

Venting Arrangements - Vertical Terminations

with Co-linear Flex System for both
Residential & Manufactured Homes

into Masonry Fireplaces

The shaded area in the diagram shows the allowable vertical
terminations.
Note: Must remove 4 screws from stove collar
and rotate 130

o

to have collar facing straight back. Secure into

place with 4 screws.

VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum fl ue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Straight Vertical Terminations

INSTALLATION

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical

Termination

Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter Kit

which contains the following:

Co-linear

Flex

Adapter

(270-585)

Outer

Pipe

(946-257)

Inner

Pipe

Adapter

(946-219)

Alternate Approved Caps
980 Vertical

Termination

Cap

991 High

Wind

Cap

923GK 3" Co-linear Adapter with fl ashing

Vent Restrictors
set at fully open,
Posiiton "A"