Heath Zenith All MetAl Motion SenSor HD-9260 User Manual

Page 7

Advertising
background image

--

598-1188-02

Controlling Non-Motion Sensing Fixtures

When wiring to additional standard fixture

only: Strip the motion sensor's red wire and
connect to the standard fixture's

black wire.

Connect all white wires together. Total fixture
ratings must not exceed 1000 Watts (8.3 A).

NOTE: All wiring between fixtures should be run

in accordance with the National Electrical
Code (Canadian Electrical Code in Canada)
through conduit or another acceptable means.

Contact a qualified electrician if there is any

question as to the suitability of the system.

This fixture is provided with a sensor rated

for 1000 Watts. Since the fixture is only rated
500 Watts, 500 Watts of additional load may
be controlled by this sensor.

When determining what a fixture is rated for,

do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.

Once you have selected the fixtures to be con-

nected and determined their maximum ratings,
add these ratings up. For instance, if you have 3
fixtures rated 100 Watts, 150 Watts, and 75 Watts
respectively, you have a total load of 325 Watts.

Wiring to a Motion Light & Standard Fixture

Standard

Fixture

RED from JourneyMan

®

to

BLACK from Fixture

BLACK from Switch to

BLACK from JourneyMan

®

WHITE from Line

to

WHITE from

JourneyMan

®

WHITE from Line to

WHITE from Fixture

Advertising