Operating instructions, Cleaning / maintenance instructions, Troubleshooting – Holmes HAP 220 User Manual

Page 2: Pre-operating instructions

Advertising
background image

4. Remove protective plastic bag from the filter cartridge.
5. Return the filter to the unit by tilting the filter cartridge top toward you

as you insert the bottom of the cartridge fully into the filter recess.

NOTE: black carbon side of filter should be facing outwards. Some filters

utilize hang tabs and filter clips. The clip can only be attached to the

tabs on the filter one way only. The filter clip should easily slide onto the

filter hang tab with only a small amount of pressure. DO NOT use force

while attaching the clip to the filter. Align the clip on the top of the HEPA

filter with the rails on the inside of the purifier unit. Gently slide the

filter onto the rail. (fig. 1)

6. Replace front grill back onto unit securely.

DO NOT POINT OUTLET TOWARDS WALL.

OPERATING INSTRUCTIONS

1. Plug into a 120V AC electrical outlet.
2. Select the desired operating speed. Holmes Air Purifiers have two

or three different speed settings depending on the model you own. You

can select from HI, MED, or LOW by sliding the switch to the desired

setting. The power light will illuminate letting you know the power is on.

3. To release negative ions into the filtered air slide the ionizer switch to

ON and the light will illuminate.

4. For optimum air filtration, it is recommended to operate the air purifier

continuously. It’s rugged motor has been designed to give many years

of use.

For continuous use, it’s recommended to operate the air purifier at the

MEDIUM setting. For quieter operation or use in a bedroom, select the LOW

setting. When high levels of air pollution are present select the HI setting

to quickly circulate and filter the room air.

CLEANING / MAINTENANCE INSTRUCTIONS

CLEANING INSTRUCTIONS
Turn off and unplug the unit before cleaning.
1. The outside of the air purifier can be cleaned with a soft,

dampened cloth.

2. The front grill can be removed and washed in warm soapy water

(not dishwasher safe). Dry before replacing in the unit.

3. The top air outlet grill can be cleaned of dust with a small

soft brush.

WARNING: Do not allow moisture to come in contact with the main

housing of the air purifier.

FILTER REPLACEMENT INSTRUCTIONS
1

. Filter Check Indicator – There are three different types of indicators

used in our air purifiers. Your air purifier may have one of the follow-

ing: a filter condition sticker that serves as a color coded reference

point. A filter reminder dial that is manually set to remind the user

when it is time to replace the filter. Or an indicator light that illumi-

nates when it is time to change the filter.

2. Every few weeks, check the condition of the filters.
3. Remove the front grill. If the unit is equipped with a foam pre-filter,

examine the filter. If it has collected a noticeable amount of dust or

lint, remove it from the inlet of the grill and wash it in warm soapy

water. Rinse and drip dry the pre-filter thoroughly before replacing it

into the inlet of the grill.

4. If there is a separate carbon odor filter it should be replaced every 2-

3 months. This helps extend the life of the HEPA filter and provides

optimal odor removal.

5. With the front grill removed, check the condition of your HEPA filter. If

the filter is dirty remove the used HEPA cartridge and dispose of it in

the garbage. Do NOT try to wash and re-use the HEPA filter.

Replace with a new HEPA filter, removing the protective polybag

before inserting into the air purifier.

6. Units with a filter reminder dial should be set ahead 3-6 months

depending on usage.

7. Units which have an indicator light must be reset once

the HEPA filter has been replaced. Reset indicator by

inserting a small object (such as a pin or paperclip)

into the hole marked reset. (fig. 2)

NOTE: The pleated material and rubber gasket should

be facing towards the unit when applied.

8. Filter Life – Under normal conditions of continuous use, the HEPA

filter will operate efficiently for 3-6 months.

Replacement filters are available from your local supplier

or by calling 1-800-5-HOLMES.

TROUBLESHOOTING

Problem

Solution

Unit will not operate Check to make sure unit is properly plugged in

Check to make sure the unit is on by sliding the

power switch to the ON position, or by pressing the

power button. If applicable,check the remote con-

trol for batteries.

Decreased air flow

Check the filters to see if they are in good

condition and if they need to be changed.
Check to ensure nothing is blocking air inlet and

filtered air outlet.

When using electrical appliances, basic safety precautions should

always be followed to reduce the risk of fire, electric shock, and injury

to persons, including the following:

1. Read all instructions before using appliance.
2. To avoid fire and shock hazard, plug the appliance directly into a 120V

AC electrical outlet.

3. If the filter is covered by a bag when shipped: remove plastic bag over

filter before use.

4. Keep the cord out of heavy traffic areas. To avoid fire hazard NEVER put

the cord under rugs, near heat registers, radiators, stoves or heaters.

5. To protect against electrical hazards DO NOT immerse in water or other

liquids. Do not use near water.

6. Close supervision is necessary whan any appliance is used by, or near

children or by disabled people.

7. Always unplug the air purifier before moving it, opening the grill,

changing the filters or whenever the air purifier is not in use. Be sure

to pull by the plug and not the cord.

8. NEVER drop or insert any object into any openings.
9. Do not operate any appliance with a damaged cord or plug, if motor

fan fails to rotate, after the appliance malfunctions, or if it has been

dropped or damaged in any manner. Return appliance to manufacturer

for examination, electrical or mechanical adjustment or repair.

10. Use appliance only for the intended household use as described in this

manual. Any other use not recommended by the manufacturer may

cause fire, electric shock or injury to persons. The use of attachments

not recommended or sold by the Holmes Group may cause hazards.

11. Do not use outdoors.
12. Never block the air openings, or place on soft surface, such as bed or

sofa, as this could cause the unit to tip over, blocking the air intake

opening.

13. Keep unit from heated surfaces and open flames.
14. DO NOT attempt to repair or adjust any electrical or mechanical func-

tions on this unit. Doing so will void your warranty. The inside of the

unit contains no user serviceable parts. All servicing should be per-

formed by qualified personnel only.

15. WARNING: To reduce the risk of fire or electrical shock, DO NOT use

this air purifier with any solid-state speed control device.

CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS
The length of cord used on this appliance was selected to reduce the

hazards of becoming tangled in, or tripping over a longer cord. If a longer

cord is necessary an approved extension cord may be used. The electrical

rating of the extension cord must be equal to or greater than the rating of

the air purifier. Care must be taken to arrange the extension cord so that it

will not drape over the countertop or table-top where it can be pulled on

by children or accidentally tripped over.

Congratulations on your purchase of an Air Purifier. Your Air Purifier

has an attractive stylish design. It’s versatility and quiet operation

make this unit perfect for both the home and the office.
OPTIONAL ODOR FILTER

1.) An optional odor filter can be installed in your air purifier. This

filter helps remove unpleasant odors, and extends the life of your main

HEPA filter.

2.) Specialized odor filters are available for targeted odor removal for use

in removing general purpose, smoke, pet/nursery or kitchen odors.

IONIZER
Your Air Purifier has an independently controlled ionizer, which, when

turned on, releases negative ions into outgoing filtered air. Ions are tiny

particles that carry a positive or negative charge. These ions exist naturally

around us, in the air, water and ground. Both positive and negative ions

are colorless, odorless and completely harmless.
Negative ions help the air purification process by attaching

themselves to very small airborne particles in the room. These

particles take on a negative charge and may join with positively charged

particles such as dust, pollen, smoke and pet dander to form larger

particles that are then more readily captured by the filter system, or they

may be attracted to positively charged surfaces like walls or floors.
You may also note after extended use, that dust may have collected around

the grills or front panel. This is from the ionization affect caused by the

negative ions exiting from the air outlet. This is additional evidence of the

air cleaning effectiveness of negative ions. The dust can be easily removed

with a clean, dampened cloth or soft brush.
PLEASE NOTE: It is important to replace the HEPA filter at the recommend-

ed intervals. Using the ionizer in conjunction with dirty filters may result in

dirty particles exiting the air purifier and being attracted to walls, carpets,

furniture or other household objects. These dirty particles may prove very

difficult to remove.
ADDITIONAL FEATURES
Filter Check Indicator – There are three different types of indicators used

by Holmes Air Purifiers. Your air purifier may have one of the following: a

filter condition sticker that serves as a color coded reference point. A filter

reminder dial that is manually set to remind the user when it is time to

replace the filter. Or an indicator light that illuminates when it is time to

change the filter.

PRE-OPERATING INSTRUCTIONS

1. Carefully unpack your air purifier. Select a firm level place where there are

no obstructions to the air inlet (front grill) or filtered air outlet (top of unit).

A good location in a room is about 2 feet above the floor and approxi-

mately 1 foot away from the wall, in a central location of your home.

2. Removal of the front grill varies with different models. Depending on

the model you own you will need to do the following: Press grill release

buttons on either side of the grill and pull forward, OR pull grill towards

you by grasping sides of the grill.

3. Remove HEPA filter by gripping on both sides and pulling forward.

THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC
(Alternating Current) PLUG (a plug having one blade wider
than the other). This plug will fit into the power outlet only
one way. If the plug does not fit fully into the outlet,
reverse the plug. If it still does not fit, contact qualified
personnel to install the proper outlet. DO NOT DEFEAT THE
SAFETY PURPOSE OF THIS POLARIZED PLUG IN ANY WAY.

PLEASE READ AND SAVE THESE IMPORTANT

SAFETY INSTRUCTIONS

FEATURES - OPERATIONS

Figure 1

Figure 2

PLEASE READ AND SAVE THESE

IMPORTANT SAFETY INSTRUCTIONS

HMAN075.01.US.OM1 12/17/01 3:44 PM Page 2

Advertising