Heath Zenith Motion Sensor Light Control SL-5412 User Manual

Motion sensor light control, Operation, Model sl-5412

Advertising
background image

© 2007 HeathCo LLC

598-1265-01

Requirements

• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be

wired through a switch.

Some codes require installation by a qualified
electrician.

• This product is intended for use with the enclosed

gasket and with a junction box marked for use in wet
locations.

Model SL-5412

Light Control

Sensor

Cover

Plate

Lamp Holders

2 Wire

Connectors

6 Screws

(3 sizes included)

Gasket

2 Shells

Features

• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight

hours.

• LED indicates motion was sensed (day or night).

Motion Sensor Light
Control

Mounting Bolt

Mounting Strap

Plastic

Hanger

Rubber Plug

OPERATION

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1

1

/

2

minutes for

the circuitry to calibrate.

MANUAL MODE

ON-TIME

10 5 1 TEST

10 5 1

TEST

ON-TIME

TEST

... back on.

AUTO

1 Second OFF

then...

Put the ON-TIME switch in the 1, 5,
or 10 minute position.

Put the ON-TIME switch on the bottom
of the sensor in the TEST position.

Manual mode only works at night
because daylight returns the sensor
to AUTO.

Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.

Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.

Move ON-TIME Switch to

1, 5, or 10 minutes

Mode Switching Summary

Flip light switch off

for one second then

back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

This package includes:

As an ENERGY STAR

®

Partner, Heath

®

/Zenith

has determined that this product meets the EN-
ERGY STAR

®

guidelines for energy efficiency.

This product is ENERGY STAR

®

compliant

when used with 120 Watt bulbs.

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Minutes

x

Manual

To Dawn*

x

2 Flood Lamps

(some versions)

Advertising