Tr oub leshooting guide – Honeywell CM907 User Manual

Page 17

Advertising
background image

16

17

Tr

oub

leshooting Guide

Symptom

CM907 has a blank LCD scr

een

CM907 shows a flashing

symbol on the LCD scr

een

The CM907’

s LCD scr

een

works but the heating does not switch on

Heating switches ON or OFF too slowly or quickly

Temperatur

e swings between

too hot and too cold.

CM907 shows a flashing

symbol on the LCD

scr

een

P

ossib

le Cause

Batteries not installed

Incorr

ect batter

y orientation

Exhausted batteries

Batteries ar

e exhausted and

need r

eplacing

No power to heating system

Pr

ogram does not call for

heat

CM907 not connected to boiler pr

operly

CM907 not set corr

ectly for

your system

CM907 not set corr

ectly for

your system

Fault in CM907

Remed

y

Check to see if ther

e ar

e batteries in the batter

y

compar

tment and the paper tab has been r

emoved

Check that the batteries have been installed in the corr

ectorientation

Replace with new batteries

Replace with new batteries

Check that ther

e is power to the heating system.

Move the slider switch to

MAN

and pr

ess

or to

incr

ease the temperatur

e a few degr

ees above the

curr

ent r

oom temperatur

e. The heating should come

on after a few seconds.

Call installer to check electrical connection between the CM907and the boiler

.

Call Installer

Call Installer

Remove and r

e-inser

t the batteries in the CM907.

If the

symbol does not clear itself in a few

minutes call the installer

Advertising