Select wash frequency, Wiring, Warning – Honeywell W8600F User Manual

Page 3

Advertising
background image

W8600F AIR CLEANER MONITOR

3

69-1200—2

Select Wash Frequency

Use the W8600F DIP switches to program the time
between SERVICE indications. Be sure to select the
setting according to the conditions of the home. Factors
to consider include the duty cycle of the EAC, the
number of people and pets, and activities such as
woodworking and other crafts that are being done in the
home.

Refer to Table 2 to select the wash frequency. Set the
W8600F DIP switches to match the selection. See Fig. 4.
The time listed represents actual run time of the EAC, not
calendar days.

Fig. 4. Back of W8600F.

Wiring

1.

Run a 3 -conductor thermostat cable (up to
18 gauge) from the W8600F to the terminal strip on
the air cleaner.

IMPORTANT

Connect cable to W8600F before attaching to
the air cleaner terminals to minimize the risk of
damage due to static electricity.

2.

Connect the wires to terminals E1, E3 and E4 on
the W8600F. See Fig. 4.

3.

Check that the battery is correctly installed in the
W8600F battery holder.

4.

Snap the W8600F onto the base.

5.

Turn off the power for the EAC.

WARNING

Electric Shock Hazard.
Can cause electrical shock or equipment
damage.
Disconnect EAC power and open the access
door before opening power supply box cover.

6.

Open the power supply box cover.

7.

Remove the plug from the side of the power supply
box (plug can be a metal knockout or a blank termi-
nal strip).

8.

Install the terminal block/cable assembly supplied
with W8600F kit.

9.

Plug the connector on the end of the cable assem-
bly into the J2 terminal on the driver board
(included with W8600F kit). See Fig. 5.

Fig. 5. Installing the driver board on the EAC.

10.

Plug the driver board assembly into the J1 power
supply connector.

NOTE:

This W8600F kit is configured to operate with a
power supply that is controlled by an airflow
switch (AFS). If your application does not have
an AFS, place the black shorting bar (found in
the bag assembly) on power supply connector
J3, pins 1 and 2, as shown in Fig. 6.

Fig. 6. Placing shorting bar on power supply for

applications without AFS.

11.

Replace the power supply box cover.

Table 2. Wash Frequency Options.

DIP Switch Settings

Wash Frequency

1

2

3

Days (Run Time)

Off

Off

Off

10

On

Off

Off

20

Off

On

Off

30

On

On

Off

40

Off

Off

On

50

On

Off

On

70

Off

On

On

100

On

On

On

180

M11969A

BATTERY
IN HOLDER

DIP SWITCHES

RESET BUTTON

WIRING
TERMINALS (3)

BACK OF W8600F

1

3

4

1 2 3

UP

M11970

ELECTRONIC AIR CLEANER

SYSTEM

J2

J1

DRIVER
BOARD

TERMINAL
STRIP

MOUNTING
SCREW

POWER SUPPLY BOX

POWER SUPPLY
BOX COVER

POWER
SUPPLY

4

J3

M20890

SHORTING BAR

3

2

1

69-1200-2.fm Page 3 Tuesday, December 3, 2002 11:21 AM