SPECIFICATIONS

Range . . . . . . . . . . . Up to 30 ft. (9.1 m)

[varies with surrounding
temperature].

Sensing Angle . . . . . Up to 150°, 240°

adjustable

Electrical Load . . . . . See rating on fixture

for maximum wattage

Sensor Capacity . . . Up to 360 Watts (3.0

A.) Maximum

Power Requirements 120 VAC, 60 Hz
Operating Modes . . . TEST, AUTO, and

MANUAL MODE

Time Delay . . . . . . . 1, 5, 10 minutes
D

ual

B

rite

®

Timer . . . 3, 6 hours, dusk-to

dawn

DESA Specialty Products reserves the
right to discontinue products and to change
specifications at any time without incurring
any obligation to incorporate new features
in products previously sold.

SYMPTOM
Light stays on
continuously.

Light flashes
on and off.

POSSIBLE CAUSE
1. The sensor is pointed at nearby

objects that cause heat to trigger
the sensor. (Aim the sensor
away from nearby objects.)

2. The sensor is pointed toward

a heat source like an air vent,
dryer vent, or brightly-painted
heat-reflective surface. (Re-
aim sensor.)

1. Heat being reflected from other

objects may be affecting the
sensor. (Re-aim sensor.)

POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker

is turned off.

4. Daylight turn-off is in effect

(recheck after dark).

5. Incorrect circuit wiring, if this

is a new installation.

6. Re-aim the sensor to cover

desired area.

1. Light Control may be installed

in a relatively dark location.

2. Light Control is in Test. (Set

control switch to an ON-TIME
position.)

1. Light Control may be sensing

small animals or automobile
traffic (re-aim sensor).

2. Sensitivity is set too high.

(Reduce sensitivity.)

SYMPTOM
Light will not
come on.

Light comes
on in daylight.

Light comes
on for no ap-
parent reason.

TROUBLESHOOTING GUIDE