Stacking condenser unit – Hoshizaki KM-501MRH User Manual

Page 16

Advertising
background image

16

5. Stacking Condenser Unit

1) Secure the lower condenser unit to the legs with eight bolts (not included).
2) Attach the upper condenser unit on the top of the lower.
3) Secure the upper condenser unit with the four screws provided.
4) Install refrigerant lines, and make electrical connection for each fan motor as shown in

Items 3. and 4.

Fig. 8