Screw-in type – Honeywell TRADELINE Q314 User Manual

Page 2

Advertising
background image

2

CONNECT PILOT GAS TUBING

1. Cut tubing to desired length and bend as necessary for

routing to pilot burner. Do not make sharp bends or deform
tubing. Do not bend tubing at control after compression nut
has been tightened, as this can result in gas leakage at
connection.

2. Square off and remove burrs from end of tubing.
3. Push tubing into compression nut clearance hole until

tubing bottoms.

NOTE: When replacing a pilot burner or orifice, cut off old

compression fitting and replace with new compression
fitting provided with new pilot burner. Never use old
compression fitting as it may not provide a gas-tight seal.
See Fig. 3.

4. While holding tubing all the way in, engage threads

and turn until finger tight.

5. Using a wrench, turn compression nut one turn beyond

finger tight. DO NOT OVERTIGHTEN.

6. Connect other end of tubing to gas control according to

gas control manufacturer instructions.

Fig. 3—Always use new compression fitting.

Fig. 2—Location of pilot burner.

PILOT BURNER/
IGNITION-
SENSOR
JUST RIGHT

PILOT BURNER/
IGNITION-
SENSOR
TOO LOW

PILOT BURNER/
IGNITION-
SENSOR
TOO HIGH

MAIN BURNER
FLAME WILL
IMPINGE ON
IGNITION-
SENSOR

IGNITION
FLAME WILL
IMPINGE ON
MAIN BURNER

IGNITION
FLAME JUST
MISSES
MAIN BURNER

M3285

PILOT BURNER BODY

TIGHTEN NUT ONE
TURN BEYOND
FINGER TIGHT

FITTING BREAKS OFF
AND CLINCHES TUBING
AS NUT IS TIGHTENED

TO GAS CONTROL

M3295

INSTALL THERMOCOUPLE OR THERMOPILE
PUSH-IN DESIGN

1. Insert thermocouple or thermopile tip into hole or

barrel provided beneath pilot burner. See Fig. 4.

2. Push in firmly until thermocouple or thermopile is

locked into place.

ATTACHMENT NUT DESIGN

1. Insert thermocouple or thermopile tip into hole or

barrel provided beneath pilot burner. See Figs. 4 and 5.

2. Engage attachment nut threads and tighten until ther-

mocouple or thermopile is locked into place.

Fig. 4—Installing thermocouple or thermopile.

PILOT BURNER
ASSEMBLY

THERMOCOUPLE
OR THERMOPILE

PUSH-IN
CLIP

M3286

OPTIONAL
ATTACHMENT
NUT

INSTALL BLEED GAS TUBING (if used):

1. Route bleed gas tubing from bleed tapping on gas

control to the pilot burner.

2. Push clip into place. See Fig. 6.
3. Insert bleed gas tubing until 3/8 inch [10 mm] of tubing

is above pilot burner bracket. Tip of bleed gas tubing must not
extend into pilot flame.

INSTALL “A” MOUNTING BRACKET ADAPTER
(optional)

To convert mounting bracket from “B” mounting bracket

to “A” mounting bracket, install the “A” mounting bracket
adapter to the pilot burner mounting bracket. Then install
pilot burner to main burner.

Fig. 5—Installing Q390 Thermocouple.

SCREW-IN TYPE

THERMOCOUPLE

ATTACHMENT NUT

M3269

ADAPTER

PILOT BURNER
ASSEMBLY

Advertising
This manual is related to the following products: