Performance data, Model hgt hot gas defrost | 60 hz, Model hgt hot gas defrost | 50 hz – Heatcraft Refrigeration Products BN-LOPTB User Manual

Page 8

Advertising
background image

8

Performance Data

Model HGT

Hot Gas Defrost | 60 Hz

Model

Capacity

Fan Data

10°F TD

-0°F SST

6°c tD

-29°c sst

No.

CFM

m

3

H

BTUH

watts

6 F

ins P

er I

nch

HGT035

3,500

1,025

1

700

1,189

HGT040

,000

1,170

1

700

1,189

HGT047

,700

1,380

1

650

1,104

HGT065

6,500

1,900

2

1,00

2,379

HGT075

7,500

2,200

2

1,300

2,209

HGT090

9,000

2,640

2

1,300

2,209

HGT120

1,000

3,520

3

,100

3,568

HGT140

1,000

4,100

3

1,950

3,313

HGT160

16,000

4,690

4

,600

4,418

HGT180

18,000

5,280

4

,600

4,418

HGT200

0,000

5,860

5

3,50

5,522

HGT240

,000

7,030

6

3,900

6,627

HGT280

8,000

8,200

6

3,900

6,627

 F

ins P

er I

nch

HGT041

,100

1,200

1

690

1,172

HGT068

6,800

2,000

2

1,380

2,345

HGT080

8,000

2,340

2

1,380

2,345

HGT102

10,00

2,990

3

,170

3,687

HGT136

13,600

3,990

4

,760

4,690

HGT170

17,000

4,980

5

3,50

5,862

HGT204

0,00

5,980

6

,10

7,035

HGT235

3,500

6,880

6

,10

7,035

Model HGT

Hot Gas Defrost | 50 Hz

Model

Capacity

Fan Data

10°F TD

-0°F SST

6°c tD

-29°c sst

No.

CFM

m

3

H

BTUH

watts

6 F

ins P

er I

nch

HGT035

3,35

974

1

630

1,070

HGT040

3,800

1,113

1

630

1,070

HGT047

,65

1,308

1

586

995

HGT065

6,175

1,809

2

1,60

2,142

HGT075

7,15

2,087

2

1,170

1,989

HGT090

8,550

2,504

2

1,170

1,989

HGT120

11,00

3,339

3

1,891

3,213

HGT140

1,950

3,313

3

1,756

2,984

HGT160

,600

4,418

4

,31

3,978

HGT180

,600

4,418

4

,31

3,978

HGT200

3,50

5,522

5

,97

4,973

HGT240

3,900

6,627

6

3,51

5,967

HGT280

3,900

6,627

6

3,51

5,967

 F

ins P

er I

nch

HGT041

690

1,172

1

61

1,056

HGT068

1,380

2,345

2

1,3

2,111

HGT080

1,380

2,345

2

1,3

2,111

HGT102

,170

3,687

3

1,95

3,320

HGT136

,760

4,690

4

,85

4,223

HGT170

3,50

5,862

5

3,107

5,279

HGT204

,10

7,035

6

3,78

6,334

HGT235

,10

7,035

6

3,78

6,334

For EC motors, use 60 Hz capacity and airflow values (Units with EC motors

operating at 50 Hz will not see a reduction in performance due to the electronic

control of the motor)

NOTE: When using the hot gas units with a hot gas

loop drain pan on 0°F applications and below, an

insulated drain pan is required.

Capacity Correction Factors For

Electric and Hot Gas Defrost Units

Saturated Suction

Temperature °F

+20

-10

-20

-30

Saturated Suction

Temperature °C

-7

-23

-29

-34

Multiply Capacity

by

1.15 1.04 1.00 0.90

Advertising