Theory of operation – Homelite HP155A User Manual

Page 5

Advertising
background image

5

101568

Air For Combustion
And Heating

Fuel

THEORY OF

OPERATION

The Fuel System:

The hose/regulator assembly attaches to the propane gas

supply. The propane gas moves through the solenoid valve and out the nozzle.

The Air System:

The motor turns the fan. The fan pushes air into and around

the combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System:

The direct spark ignitor (DSI) sends voltage to the

ignitor. The ignitor ignites the fuel and air mixture.

The Safety Control System:

This system causes the heater to shut down if the

flame goes out.

Cool Air In
(Back)

Figure 2 - Cross Section Operational View

Hose/Regulator
Assembly

Solenoid
Valve

DSI

Nozzle

Clean
Heated
Air Out
(Front)

On/Off Switch

Power
Cord

Combustion
Chamber

Ignitor

Fan

Motor

Advertising
This manual is related to the following products: