Step 9. wiring the fireplace – Heat & Glo Fireplace GEM42 User Manual

Page 24

Advertising
background image

24

Heat & Glo • GEM42 • 371-900 Rev. N • 2/05

!

!

Figure 26. Intermittent Pilot Ignition (IPI) Wiring Diagram

NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts.
120 VAC is required at junction box unless equipped with battery back-up.

Wall Switch

Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the fireplace ON/
OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.

Intermittent Pilot Ignition (IPI) Wiring

3 Volt Transformer
This appliance comes with a factory installed 3 volt trans-
former.

Operation with Battery Back-up
This appliance comes with a factory installed battery back-
up.

Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
factory installed junction box. Maintain correct polarity when
wiring the junction box.

WARNING: DO NOT CONNECT 110-120 VAC
TO THE GAS CONTROL VALVE OR THE AP-
PLIANCE WILL MALFUNCTION AND THE
VALVE WILL BE DESTROYED
.

Optional Accessories

Optional remote control kits require that 110-120 VAC be
wired to the factory installed junction box before the fire-
place is permanently installed.

Heat-Zone and Heat-Out kits are approved with this fire-
place as heat management accessories.

Step 9. Wiring the Fireplace

NEUTRAL

GROUND

REMOTE

CONTROL

HOT

LOW VOLTAGE

SEE NOTE 1

ON/OFF

WALL SWITCH

VALVE

BROWN

BROWN

RED

ORANGE

GREEN

BLACK

OPTIONAL

BATTERY
BACK-UP

ORANGE (IGNITOR)

WHITE (SENSOR)

BLACK

GROUND TO

FIREPLACE

CHASSIS

PILOT ASSEMBLY

AND VALVE ASSEMBLY

MUST BE GROUNDED

(COMMON GROUND

WITH FIREPLACE

CHASSIS)

SPARK TO

PILOT IGNITOR

IGNITOR

MODULE

3V

JUNCTION BOX

TRANSFORMER

3V

TRANSFORMER OUTLET

PLUG-IN

3V TRANSFORMER

FLAME SPARKER /

SENSOR

LOW VOLTAGE

SEE NOTE 1

OPTIONAL

BATTERY
BACK-UP

IGNITION
MODULE

(3V)

ON/OFF

SWITCH

I

S

Advertising