Step 8, Wire wallplate terminals, Installation – Honeywell CT3455 User Manual

Page 13

Advertising
background image

21

69-0733—3

NOTE: All wiring must comply with local codes

and ordinances. If unsure about household
wiring procedures, call your local heating/air
conditioning contractor.

Refer to masking tape labels you placed on
wires when you removed your old thermostat.

Match the letter of your old thermostat wire

with the terminal of the corresponding letter on
your new thermostat. Refer to illustrations on
pages 22 and 23.

In 5-wire installations only, be sure to re-
move the factory-installed jumper connect-
ing terminals R and Rc.

STEP 8

Wire Wallplate Terminals

INSTALLATION

22

69-0733—3

Loosen the terminal screws and slip each

wire beneath its matching terminal. Either
straight or wraparound wiring connections are
acceptable (see illustration). Tighten terminals.

Plug the hole in the wall with insulation to

help prevent drafts from adversely affecting
thermostat operation.

M2486

FOR STRAIGHT INSERTION–
STRIP 5/16 IN. (8MM)

FOR WRAPAROUND–
STRIP 7/16 IN. (11MM)

M612A

THERMOSTAT

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.

1

2-WIRE HEAT-ONLY (JUMPER INTACT)

HEATING
RELAY OR
VALVE COIL

W G

R RC

Y

M614A

THERMOSTAT

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.

1

4-WIRE HEAT/COOL (JUMPER INTACT)

HEATING
RELAY OR
VALVE COIL

COOLING
CONTACTOR
COIL

FAN
RELAY

W G

R RC

Y