Hearth & Home Technologies • GFK21B Fan Kit • 4016-096 Rev I • 11/08

3

Robertshaw Valve (Standing Pilot)

- Connect the black, white and red wires with 1/4 in.

female connectors from the fan control module to the
appliance junction box as shown in Figure 9.

- Connect the black ground wire with the ring terminal

to the TP screw on the valve (center).

- Remove wall switch wire connected to valve terminal

marked “TH”.

- Connect the black with white stripe wire with 3/16 in.

piggyback connector from fan control module to valve
terminal marked “TH”.

- Connect wall switch wire removed from valve terminal

“TH” to the piggyback connector on the black with white
stripe fan control module wire.

3. Install the Fan

Position the fan all the way to the rear and center in the ap-
pliance. Press the fan (magnets to the bottom) to the back of
the appliance. See Figure 7. Plug the fan cord into the fan
receptacle labeled “FAN” on the junction box. See Figure 8.

BOTTOM PAN

APPLIANCE

BACK

FAN

FIREBOX

BOTTOM

Figure 7

Rotate Fan

Junction Box

Fan Assembly

Cord

Clips

Figure 8

Position the Fan

4. Install the Control Module

Attach the control module to the bottom pan using the mag-
netic tape provided.

2. Remove Valve Assembly

On a Novus 30 in. appliance (GNDC30 or GNBC30 only) the
valve assembly must be raised slightly to allow the fan to be
moved past it to the back of the appliance.

5. Wiring the Fan Control Module

Wall

Switch

RS

Valve

TP

TH

TH

TP

Fan

Control
Module

Black/White

Black Ground

Black

Red

White

Thermopile

Red

White

Figure 9

Robertshaw Wiring Diagram

Note: Fan control timer only for use on units with junction
box pictured in Figure 9.

Note: Thermopile must be wired as shown in Figure 9.