598-1266-01

SYMPTOM
Light will not
come on.

Light comes on
in daylight.

Light comes on
for no apparent
reason.

POSSIBLE CAUSE
1. The halogen lamp is positioned too

close to the light control’s sensor or
pointed at nearby objects that cause
heat to trigger the sensor (Reposition
the lamp away from the sensor or
nearby objects)
.

2. Light control’s sensor is pointed toward

a heat source like an air vent, dryer
vent, or brightly-painted heat-reflective
surface (Reposition sensor).

3. On-time set too high (Reduce Time

setting).

1. Heat or light from the halogen lamp

may be turning the light control on
and off (Reposition the lamp away
from the sensor)
.

2. Heat being reflected from other

objects may be affecting the light
control (Re-aim sensor).

3. Light control is in the TEST mode

and warming up (Flashing is normal
under these conditions)
.

SYMPTOM
Light stays on
continuously.

Light flashes
on and off.

POSSIBLE CAUSE
1. Light switch is turned off.
2. Halogen lamp is loose or burned

out.

3. Fuse is blown or circuit breaker is

turned off.

4. Daylight turn-off is in effect (Recheck

after dark).

5. Incorrect circuit wiring, if this is a new

installation.

6. Not aimed correctly (Re-aim the

sensor to cover desired area).

1. Light control may be installed in a

relatively dark location.

2. Light control is in TEST (Select 1, 5

or 10 minutes for AUTO time).

1. Light control’s sensor may be detect-

ing small animals, swaying trees, or
automobile traffic (Re-aim sensor).

2. Sensitivity is set too high (Reduce

sensitivity).

TROUBLESHOOTING GUIDE