– 31

MAINTENANCE

Starter

Changing a broken or worn starter cord

Loosen the screws that hold the starter against the
crankcase and remove the starter.

Pull out the cord approx. 30 cm and hook it into the notch
in the rim of the pulley. Release the recoil spring by letting
the pulley rotate slowly backwards.

Undo the screw in the centre of the pulley and remove the
pulley. Insert and fasten a new starter cord to the pulley.
Wind approx. 3 turns of the starter cord onto the pulley.
Connect the pulley to the recoil spring so that the end of
the spring engages in the pulley. Fit the screw in the
centre of the pulley. Insert the starter cord through the
hole in the starter housing and the starter handle. Make a
secure knot in the end of the starter cord.

Tensioning the recoil spring

Hook the starter cord in the notch in the pulley and turn
the starter pulley about 2 turns clockwise.

CAUTION! Check that the pulley can be turned at least a
further 1/2 turn when the starter cord is pulled all the way
out.

Changing a broken recoil spring

Lift off the pulley. See instructions under heading
Changing a broken or worn starter cord.

Remove the recoil spring from inside the pulley by tapping
the pulley lightly with its inside face downwards against a
work bench or the like. If the spring pops out during fitting,
wind it up again, working from the outside in towards
centre.

Lubricate the recoil spring with light oil. Fit the pulley and
tension the recoil spring.

Fitting the starter

To fit the starter, first pull out the starter cord and place the
starter in position against the crankcase. Then slowly
release the starter cord so that the pulley engages with
the pawls.

Fit and tighten the screws that hold the starter.

!

WARNING! When the recoil spring is wound
up in the starter housing it is under tension
and can, if handled carelessly, pop out and
cause personal injury. Always be careful
when changing the recoil spring or the
starter cord. Always wear protective
goggles.