7. Using depth gauge (Fig. 14)

(1) Loosen the knob on the side handle,

and insert the depth gauge into the
mounting hole on the side handle.

(2) Adjust the depth gauge position ac-

cording to the depth of the hole and
tighten the knob bolt securely.

8. How to use the drill bit (taper shank)

and the taper shank adaptor.

(1) Mount the taper shank adaptor to the

rotary hammer. (Fig. 15)

(2) Mount the drill bit (taper shank) to the

taper shank adaptor. (Fig. 15)

(3) Turn the switch ON, and drill a hole in

prescribed depth.

(4) To remove the drill bit (taper shank),

insert the cotter into the slot of the taper
shank adaptor and strike the head of
the cotter with a manual hammer sup-
porting on the rests. (Fig. 16)

Grip

Fig. 13

Fig. 15

Drill Bit

Taper shank
Adaptor

Front Cap

Grip

Knob on Side
Handle

Cotter

Rests

Taper Snank Adaptor

Fig. 16

Fig. 14

Mounting
Hole

Depth
Gauge

Advertising