Problem

Possible Cause

Remedy

[4] Gear motor overload

protector operates
frequently or fuse
blows frequently.

a)Power Supply

. Not within

specifications.

. Refer to nameplate and

correct.

b)Evaporator Assembly

. Bearings or auger

worn out.

. Replace bearings or

auger. See "V.F.. Upper
Bearing Wear Check."

c) Bin Control

. Bad contacts.

. Check for continuity and

replace.

. Actuator does not

move freely.

. Clean actuator or replace

bin control assembly.

d)Safety Switch and

Relay

. Switch misaligned,

contacts bad.

. Check and correct or

replace.

e)Control Board

. Erratic operation of

gear motor relay.

. See "II.D.4. Control Board

Check Procedure."

4. Dispensing

Problem

Possible Cause

Remedy

[] No ice dispensed.

a) Power Supply

. "OFF" position.

. Move to "ON" position.

. Loose connection.

. Tighten.

3. Bad contacts.

3. Check for continuity and

replace.

4. Not within

specifications.

4. Refer to nameplate and

correct.

b) Ice Storage

. No ice or little ice in

storage bin.

. Make ice.

. Ice bridge or ice block

formed.

. Melt ice, resupply with

new ice.

3. Agitating motor

defective.

3. Check, replace.

c) Ice Dispense Switch

. Opti Serve sensor

defective. (OS only)

. See "5. Opti Serve (OS)

Sensors."

. Bad contacts. (push

button only)

. Check for continuity and

replace.

d) Shutter Assembly

. Broken part.

. Check and replace.

. Open windings on

solenoid.

. Check continuity and

replace.

e) Dispense Gear Motor

. Thermal protector is

tripped.

. Allow to cool.

. Gear motor winding

open.

. Replace.

3. Bearing worn out.

3. Replace.

4. Wiring to gear motor. 4. Check for loose

connection or open
circuit, and replace wiring
as needed.

5. Defective capacitor.

5. Replace.

f) Auger Mechanism

. Bad alignment of

auger.

. Realign.

g) Control Board

. Defective.

. See "II.D.4. Control

Board Check Procedure."