3

595-4881-10

USING MOTION SENSOR

WALL SWITCh

MOdE SELECTION SWITCh

This switch allows you to selects one of three

modes of operation: OFF, AUTO, or ON.

OFF:

Lights stay off.

AUTO:

Lights automatically come on when

motion is detected and the existing light is below

the set level.

ON:

Lights stay on continuously.

AdJUSTMENTS

Time

There are 6 preset selections for the amount of

time the lights stay on: Test (5 seconds), 1, 5, 10,

15, and 20 minutes. Use a small, phillips screw

driver to adjust the TIME control (see Figure 4).

Turn the TIME control until it “snaps” into the

desired time position.

Light Level

You can adjust the sensor’s sensitivity to existing

light. Use a small Phillips screw driver to adjust

the LIGHT control (see Figure 4). By turning the

control fully clockwise, the sensor will turn lights

on even in full daylight. By turning the control fully

counterclockwise, the sensor will only turn lights

on when the existing light is very low.

Adjusting the Photocell

1. When the existing light in the room is at the

level you want the lights to turn on, set the mode

selection switch to the AUTO position.

2. Adjust the TIME control to the 5 second posi-

tion.

3. Adjust the LIGHT control to the minimum

dark position (fully counterclockwise).

4. Wait for the lights to turn off.

5. Slightly turn the LIGHT control clockwise.

Wait 2 seconds, then move your hand in front

of the sensor. If lights controlled by the sensor

do not come on, repeat this step until they do.

The light will now come on when the light level

is at or below the present level and motion is

detected.

COMPLETING INSTALLATION

1. Replace control panel cover and attach the

decorative wall plate. In installations where

the Heath

®

/Zenith motion sensor switch is

combined with other switches or outlets on

an expanded box, you will need to purchase

a combination wall plate. Various combination

wall plates are available at home centers and

electrical supply stores.

2. Slide the mode selection switch a couple times

to make sure it moves freely.

SPECIFICATIONS

Electrical Input ................................................................................................................120V, 60 Hz.

Fluorescent Load ...................................30 Watts minimum, Up to 400 Watts Maximum Rapid Start

Motor Load ...................................................................................................Up to 1/8 HP Maximum

Incandescent .......................................................................... Up to 500 Watts Maximum at 120VAC

On-Time ..........................................................................Adjustable approximately 5 sec. to 20 min.

Photocell Sensor ........................................................................ From full daylight to less than 1 FC.

Coverage ................................ up to 15 ft. (4.6 m) at 150°, up to 30 ft. (9.1 m) in front of the sensor

T I M E

L I G H T

+

Test

20

15

1

5

10

5 Seconds

Any Light Level

20 minutes

Dark (low light level)

Figure 4 - Time and Light Adjustments

DESA Specialty Products reserves the right to discontinue products and to change specifications at any