Т³гж 17, Special remarks – Hisense Group KFR 2601GW/BPE User Manual

Page 17

Advertising
background image

15

Special Remarks

Heating ( ) Operation

Heating performance

Defrosting

POWER Lamp

¡ñ Because this air conditioner heats a room by drawing on the heat of the outside air
(Heat pump system), the heating efficiency will fall off when the outdoor temperature

is very low. If sufficient heat cannot be obtained with this air conditioner, use another

heating appliance in conjunction with it.

¡ñ When the outdoor temperature is low, frost or ice may from in the heat exchanger
coil, reducing heating performance. When this happens, a microcomputer defrosring

system will operate. At the same time the fan on the indoor unit stops ( or runs at

very low speed in some cases). Heating operation restarts after several minutes.

(This interval will vary slightly depending upon the outdoor temperature and the way

in which frost froms).

¡ñ For several minutes after the start of heating operation, the indoor fan will not start
running unit the indoor heat exchanger coil has warmed up sufficiently. This is

because the COLD SRAFT PREVENTION SYSTEM is operating.

¡ñ The POWER lamp also remains lit during defrosting or when the compressor has
been turned off by the thermostat when the system is in the heating mode.

¡ñ In the event of power failure, the unit will stop. When the power is resumed,
the unit will restarted automatically after three minutes.

¡ñ In heating or cooling operation. Some plastic parts may expand of shrink due to a
sudden temperature ahange. In this event, a clicking sound may occur. This is normal,

and the sound will soon disappear.

¡ñ The remote control unit sends the temperature signal to the air conditioner regularly
at three-minute intervals. If the signal from the remote control unit stops for more

than ten minutes due to the loss of the remote control unit or other trouble, the air

conditioner will switch to the temperature sensor which is built into the indoor unit

and control the room temperature. In three casses, the temperature around the

remote control unit may differ from the temperature detected at the air conditioner¡¯s

position.

Power failure
during operation

Clicking Sound

clicking Sound is

heard from the air

conditiner

Remote Control Unit

Advertising
This manual is related to the following products: