Holmes HM729 User Manual

Page 2

Advertising
background image

19.Do not use humidifier in an area where humidity level

is in excess of 50%. Use a hygrometer, available at
your local retailer or through the manufacturer, to
measure the humidity.

20. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed

by qualified personnel only.

21. Never place housing under water flow or immerse in

liquids.

22. Do not plug in the cord with wet hands: electric shock

could result.

23. Do not pour water in any openings other than the

water tank.

24. To prevent damage to surfaces, do not place

humidifier under overhanging surfaces.

25. NEVER operate unit without water in the tank.
26. Do not move unit after it has been used until unit

cools completely.

27. Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information
NOTE:
This is an electrical appliance and requires

attention when in use.
NOTE: If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has

plenty of humidity and additional moisture may cause

damage.
NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected to

reduce the hazards of becoming tangled in, or tripping

over a longer cord. If a longer cord is necessary an

approved extension cord may be used. The electrical

rating of the extension cord must be equal to or greater

than the rating of the humidifier (refer to the rating

artwork placed on the humidifier). Care must be taken to

arrange the extension cord so that it will not drape over

the countertop or tabletop where it can be pulled on by

children or accidentally tripped over.

HOW COOL MIST WORKS

Your Holmes

®

Cool Mist humidifier draws dry air through

the rear air intake grill area. This air is then passed

through a moisture–laden wick filter, which retains the

minerals and deposits in the water. The resulting moist air

is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool,

invisible moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy

and uncomfortable. The recommended humidity level is

between 40%-50%.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

C L E A N I N G / M A I N T E N A N C E

S T O R A G E I N S T R U C T I O N S

When using electrical appliances, basic safety precautions

should always be followed to reduce the risk of fire,

electric shock, and injury to persons, including the

following:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance

directly into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs or near heat

registers.

4. DO NOT place humidifier near heat sources such as

stoves, radiators, and heaters. DO locate your

humidifier on an inside wall near an electrical outlet.

The humidifier should be at least 4 inches (10 cm)

away from the wall for best results.

5. NEVER place humidifier in an area where it is

accessible to children. NEVER use humidifier in a

closed room, particularly where a child may be

sleeping, resting, or playing (a closed room may

result in excessive humidity).

6. WARNING: Do not attempt to refill humidifier without

first unplugging the unit from its electrical outlet.

Failure to heed this warning may cause personal

injury. Be sure to unplug the unit by pulling on the

plug and not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings.
9. DO NOT operate any appliance with a damaged cord

or plug, after the appliance malfunctions, or if it has

been dropped or damaged in any manner. Return

appliance to manufacturer for examination, electrical

or mechanical adjustment, or repair.

10. Use appliance only for intended household use as

described in this manual. Any other use not

recommended by the manufacturer may cause fire,

electric shock, or injury to persons. The use of

attachments not recommended or sold by the

manufacturer may cause hazards.

11. DO NOT use outdoors.
12. Always place humidifier on a firm, flat, level surface.

A waterproof mat or pad is recommended for use

under the humidifier. NEVER place it on a rug or

carpet, or on a finished floor that may be damaged

by exposure to water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the

wall. Moisture could cause damage, particularly to

wall paper.

14. Humidifier should be unplugged when not in use.
15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit.

16. This humidifier requires daily and weekly

maintenance to operate appropriately. Refer to daily

and weekly cleaning procedures. Use only cleaners

and additives recommended by the manufacturer.

17. NEVER use detergents, gasoline, glass cleaner,

furniture polish, paint thinner, or other household

solvents to clean any part of the humidifier.

18. Excessive humidity in a room can cause water

condensation on windows and some furniture. If this

happens, turn the humidifier OFF.

CLEANING AND MAINTENANCE

INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry,

heated indoor air. To benefit most from the humidifier

and avoid product misuse, follow all instructions carefully.

Please note that this is an electrical appliance and

requires attention when in use.
In addition, if you do not follow the recommended care

and maintenance guidelines, micro-organisms may be

able to grow in the water within the water tank. You

must routinely follow the cleaning procedures that follow

in order to ensure proper, efficient operation of your

humidifier. Proper maintenance and cleaning is essential

to the continued performance of your unit and the

avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

1. Be sure the unit is OFF and is disconnected from the

electrical outlet.

2. Remove the tank from the humidifier and place in

sink or tub (this tank is also dishwasher safe TOP

RACK ONLY).

3. Remove the wick, drain any remaining water and

rinse thoroughly to remove any sediment or dirt.

Wipe clean and dry with a clean cloth or paper towel.

4. Put filter back in the tank, then refill with cool tap

water. Do not overfill.

WEEKLY MAINTENANCE

To Remove Scale:

1. Repeat steps 1-4 above.
2. Clean the tank by partially filling it with one 8-oz cup

of undiluted white vinegar or by using Cleanse Clean

®

solution (model S1710) by the manufacturer. Leave
this solution in the tank for 20 minutes, while
cleaning all interior surfaces with a soft brush.
Remove the scale by wiping the tank with a cloth
dampened with undiluted white vinegar.

3. Rinse clean with warm water to remove cleaning

solution before disinfecting the tank.

To Disinfect Tank
1. Fill humidifier tank 1/2 full with water and 1/2

tablespoon of chlorine bleach.

2. Let the solution stand for 20 minutes, swishing every

few minutes. Wet all surfaces.

3. Carefully empty the tank after 20 minutes, and rinse

with warm water until you can not detect any bleach

smell. Dry with a clean cloth or paper towel.

4. Place filter back into tank an refill the water tank as

directed in Operating Instructions, and turn the unit on.

STORAGE INSTRUCTIONS

When not using your humidifier for an extended period of time:
1. Dispose of the filters. DO NOT leave in unit.
2. Clean, rinse and thoroughly dry the humidifier as

directed in weekly maintenance. DO NOT leave any
water in the unit when storing. Leaving water in the
unit may render the unit inoperable for the following
season.

3. Place the humidifier in the original carton and store in a

cool, dry place.

4. Order your replacement filter for next year’s use.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched off.
2. Select a location for your humidifier, on a flat level

surface about 4 inches (10 cm) away from the wall.

DO NOT place the humidifier on a finished floor or

near furniture, which can be damaged by too much

moisture or water. Place on a moisture resistant

surface.

OPERATING INSTRUCTIONS

1. Remove the top housing from the unit and pick up

the tank.

2. Make sure the wick is in place. The rivet of the wick

will be on the bottom part of the wick and attached to

the holder.

3. Bring the tank to the sink and fill with water until the

water level reaches the fill line making sure the wick

remains in place.

4. Bring tank back to desired location and place the top

housing back onto the full tank.

5. Plug the humidifier into a 120V electrical outlet.
6. To turn the unit on, switch the knob to either the High

(II) or Low (I) setting. High will produce the

maximum moisture and Low will produce the longest

run time and quieter performance.

7. To turn the unit off, switch the knob to Off (O).

REPLACING THE FILTERS

Through normal use, waterborne minerals and sediment
become trapped in the wick filter. The harder your water,
the greater the amount of minerals in the water, and the
more often you will need to change your filter.
You will be able to monitor the life of the filter in your
humidifier by checking the FilterCheck

®

Indicator.

NOTE: After 60 minutes of use, FilterCheck

®

Indicator

will move indicate your filter condition.
A brand new filter will

register in the section

reading GOOD filter. After

frequent use of your

humidifier, the FilterCheck

®

Indicator will let you know

when the filters need to be

changed, see Figure 2.
When the needle is in the
CHANGE section, this means the proper amount of
moisture is not getting into your air due to the excessive
minerals and sediment that have become trapped on
your filters. At this point, you should replace your filter. It
is important to change your filter as indicated to obtain
stated performance level.
To Replace the filter follow the steps below:
1. Turn the unit off and disconnect from the electrical outlet.
2. Remove the top housing to access the tank.
3. Remove the wick and discard.
4. Follow the weekly cleaning instruction.
5. Insert new filter making sure the rivet is facing the bottom

of the tank and is in the rivet holder.

6. Repeat Operating Instructions.

It will take about 30 minutes for the humidifier to reach
maximum output.
You can purchase replacement filters (model HWF100) at

a local retailer, by calling 1-800-546-5637. It is

recommended that a replacement filter is purchased for

uninterrupted use.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

R E P L A C I N G I N S T R U C T I O N S

Figure 1

A. HUMIDIFIER TANK
B. HUMIDIFIER HOUSING

C. CONTROL KNOB
D. FILTERCHECK

®

INDICATOR

D

B

C

A

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the

other). To reduce the risk of electric shock, this plug is intended to fit in

a polarized outlet only one way. If the plug does not fit fully in the

outlet, reverse the plug. If it still does not fit, contact a qualified

electrician to install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

If you have any questions regarding your product or

would like to learn more about other Holmes

®

products, please contact our Consumer Service

Department at 1-800-546-5637 or visit our website at

www.holmesproducts.com.

Figure 2

HM729G-UC_08EM2.qxd:HM729G08EFM2.qxd 6/5/08 10:03 AM Page 2

Advertising