Installation, Test and adjustment – Heath Zenith Replacement Motion Sensor SH-5407 User Manual

Page 2

Advertising
background image

-2-

598-1155-01

❒ Swing the sensor head towards the clamp

screw.

For eave mount only:

Controls

INSTALLATION

❒ Remove the existing light fi xture, if present.

These instructions show the sensor wired to fl ood-
lamps. The white sensor wire is neutral. The black
sensor wire is hot.
The red wire is the switched
"hot" wire. The lighting load (500 W, 4.2A max) is
placed across the white and red wires.

❒ After screwing the sensor into the wall plate,

connect the junction box wires to the light control
wires by twisting together and securing with wire
connectors.

M

OUNT

THE

L

IGHT

❒ Follow the instructions that came with your light fi x-

ture for mounting and adjusting the light fi xture.

❒ Keep regular PAR-38 lamps at least 1" (25 mm)

from the sensor. Halogen lamps should be kept
at least 2" (51 mm) from the sensor.

Black to Black

White to White

Red Sensor Wire to

Black Lamp Wire

Optional: Connect additional load
across the white and red wires. Total
lighting load including lampheads on
fi xture must not exceed 500W (4.2A).

Junction

Box

Lamp Holders

For under eave installation, the sensor head
must be rotated
as shown in the next two steps
for proper operation and to avoid the risk of elec-
trical shock.

❒ Rotate the sensor head clockwise 180° so

the controls face down.

Clamp Screw

Controls

Controls

If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the
ball joint. Tighten the clamp screw when done.

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1

1

/

2

minute calibration

period before it will detect motion. When
fi rst turned on, wait 1

1

/

2

minutes.

W

IRE

THE

L

IGHT

C

ONTROL

WARNING: Turn power off at circuit breaker

or fuse.