Operating instructions – Harbor Freight Tools CENTRAL PNEUMATIC 95499 User Manual

Page 10

Advertising
background image

Page 10

SKU 95499

for technical questions, please call 1-800-444-3353.

OPERAtING INStRuCtIONS

to Start the Compressor:

tOOL PRESSuRE

GAuGE (65)

SAfEty RELEASE

VALVE (61)

REGuLAtOR (66)

AttACH AIR HOSE HERE

tANK dRAIN VALVE (54)

tANK PRESSuRE

GAuGE (62)

PRESSuRE SWItCH

(63)

AIR OutLEt

VALVE (67)

fIGuRE f

1.

Check to make sure the Air Tank’s Drain Valve (54), located at the bottom of the Air
Tank (50), is fully closed. Pull on the Safety release valve to verify that it is unstuck.
(See figure f.)

Turn the Air Outlet Valve (67) to its

2.

closed position. (See figure f.)

Connect an air hose (not included) to the previously installed Quick Connector.

3.

Then, connect the other end of the air hose to the pneumatic tool (not included)
that is to be used.

(See figure f, next page.)

Plug the Power Cord (55) into the nearest 120 volt, grounded, electrical outlet.

4.

Pull

5.

up on the Pressure Switch (63) to its “StARt” position to turn on the unit.

(See figure f.)

When the Tank Pressure Gauge (62) reaches at least

6.

85 PSI, turn the Air Outlet

Valve to its

open position to allow air to the pneumatic tool. (See figure f.)

Once the air pressure reaches the pneumatic tool, observe the Tool Pressure Gauge

7.

(65). Adjust the Regulator (66) to feed the proper PSI to the tool. To do so, turn
the Regulator clockwise to increase the PSI. Turn the Regulator counterclockwise
to decrease the PSI.

(See figure f.)

NOtE:

8.

When the maximum air pressure,

115 PSI, is reached as indicated by the

Tank Pressure Gauge (62), the motor will stop. The Compressor will automatically
restart when the air pressure drops below

85 PSI. (See figure f.)

07d

Advertising