Timing chart – Hoshizaki KML "F" SERIES User Manual

Page 63

Advertising
background image

63

*

*

3. TIMING CHART

Control

Sw. in

ICE

Bin

Thermo-

stat ON

Pressure

Sw. ON

Overheat

Protect

Reset

Hi Temp Mid Temp Lo Temp Too Lo Temp Normal Too Hi Temp Lo Water

Max. Min.

60 min 5 min

Min.

Max. Max.

2 min

6 min 6 min

Max.

20 min

Time Up (60 sec)

If Float Sw. is OFF

From Defrost Cycle

When Control Sw. is turned OFF, Pressure Sw. is OFF, Thermistor Temp. exceeds t1,

or Bin Control is in full position (during first 5 minutes of freeze cycle for

mechanical bin control only *3).

To Defrost Cycle

*NOTE:

*1 The icemaker does not complete a defrost cycle in the first 2 or 3 minutes. See “II. 2. [d]
CONTROLS AND ADJUSTMENTS.”

*3 (Mechanical bin control only) The bin control will only shut off the ice machine during the first five

minutes of the freeze cyle.

*1

*1

Advertising
This manual is related to the following products: